Download Tokopedia App
Tentang TokopediaMitra TokopediaMulai Berjualan PromoTokopedia Care
tokopedia-logo
Kategori
  1. Home
  2. Kesehatan
  3. Perlengkapan Medis
  4. Alat Laboratorium
  5. ORP PH Temperature Meter 3 in 1 ORP-3569 Tester Water ORP3569 Kangen

Foto Produk ORP PH Temperature Meter 3 in 1 ORP-3569 Tester Water ORP3569 Kangen dari HRDIK
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Atur jumlah dan catatan

Stok 888

Beli ≥ 3, lebih hemat!

Tambah Catatan

Subtotal

Rp839.000

ORP PH Temperature Meter 3 in 1 ORP-3569 Tester Water ORP3569 Kangen

Terjual 7
rating 5 (3 ulasan)
Rp839.000
  • Kondisi: Baru
  • Berat: 380 Gram
  • Kategori: Alat Laboratorium
  • Etalase: Alat Ukur Air
- Dikirim dari Jakarta dengan kardus utk keamanan
- Semua produk kami bergaransi distributor Jakarta

---
Alat pengukur air 3 in 1:
1. ORP - Potensial Pengurangan Oksidasi
2. PH - Kadar Asam Basa, dan
3. Temperature - Suhu Air

Specifications:
Measuring range:
PH: 0.00-14.00pH
ORP:-1999-1999mV
Temp:0-50℃

Resolution:
PH:0.01pH
ORP:1mV
Temp:0.1℃

Acuracy:
PH:±0.1pH
ORP:±5mV
Temp:±1℃

Automatic Temperature Compensation.O℃~50℃
Batery Type:4×1.5V(AG13)
Operating Temperature:0℃~50℃
Calibration:Manual.at one point through trimmer
Dimensions:188mm×35mm×35mm
Weight: 98g


Dikirim dari Jakarta,
bergaransi distributor Jakarta

How to Calibrate

1)PH
1.Rinse the ph electrode first with distilled water,and suck it with filter paper.
2.Turn on the meter. Press the "pH/ORP"button,choice the PH for measuring.
3.Immerse the ph electrode in pH6.86(or pH7.00)buffer solution,gently shake the meter and wait for a stable display.
4.Regulate the trimmer with the screwdriver provided until display shows "6.86"("7.00")at buffer solution temperature of 25℃.
5.Rinse the ph electrode with distilled water,and suck it with filter paper (not included)
6.Immerse the pH electrode in pH4.01 or pH9.18(pH10.0)buffer solution,gently shake the electrode and waiting for the reading to stabilize.The showing value and buffer solution's ph value is within error range.
7.The calibration of the instrumen's pH range is now complete.


2)ORP
1. Turn on the meter.Press the"pH/ORP" button,choice the ORP for measuring.
2. Rinse the electrode with distilled water.
3. Immerse the electrode into the fresh 256mV ORP standard solution,then stir it gently,
4. Allow the reading to stabilize and with a small screwdriver turn the calibration trimmer until the display shows"256".
5. Rinse the electrode with distilled water and suck it with filter paper.
6. Switch off the meter.Replace the battery compartment cap.
The calibration of the instrument's ORP range is now complete.
Logo HRDIK
Power Merchant

HRDIK

• Online
4.7rating toko
± 12 jampesanan diproses
Penawaran Lainnya

Paylater & Cicilan

mulai Rp92.780, tersedia bunga 0%.

Harga Grosir

Lebih murah, mulai dari Rp829.000 min. 3 pcs
Grosir info
JumlahHarga Satuan
3Rp829.000
Ada masalah dengan produk ini?

Ulasan(3)

ORP PH Temperature Meter 3 in 1 ORP-3569 Tester Water ORP3569 Kangen

Lainnya di toko ini

Lihat Semua
Tambah ke Wishlist
PH Meter Smart Sensor AS218 Calibration Certificate Tester AS-218 basa
PH Meter Smart Sensor AS218 Calibration Certificate Tester AS-218 basa
Rp 1.358.000
HRDIK
Jakarta UtaraHRDIK
starstarstarstarstar (16)
Grosir
  • Keamanan

Ikuti Kami

icon-facebookicon-twittericon-pinteresticon-instagram
© 2009 - 2021, PT. Tokopedia.