Alat pengukur air 3 in 1:
1. ORP - Potensial Pengurangan Oksidasi
2. PH - Kadar Asam Basa, dan
3. Temperature - Suhu Air
Specifications:
Measuring range:
PH: 0.00-14.00pH
ORP:-1999-1999mV
Temp:0-50℃
Resolution:
PH:0.01pH
ORP:1mV
Temp:0.1℃
Acuracy:
PH:±0.1pH
ORP:±5mV
Temp:±1℃
Automatic Temperature Compensation.O℃~50℃
Batery Type:4×1.5V(AG13)
Operating Temperature:0℃~50℃
Calibration:Manual.at one point through trimmer
Dimensions:188mm×35mm×35mm
Weight: 98g
Dikirim dari Jakarta,
bergaransi distributor Jakarta
How to Calibrate
1)PH
1.Rinse the ph electrode first with distilled water,and suck it with filter paper.
2.Turn on the meter. Press the "pH/ORP"button,choice the PH for measuring.
3.Immerse the ph electrode in pH6.86(or pH7.00)buffer solution,gently shake the meter and wait for a stable display.
4.Regulate the trimmer with the screwdriver provided until display shows "6.86"("7.00")at buffer solution temperature of 25℃.
5.Rinse the ph electrode with distilled water,and suck it with filter paper (not included)
6.Immerse the pH electrode in pH4.01 or pH9.18(pH10.0)buffer solution,gently shake the electrode and waiting for the reading to stabilize.The showing value and buffer solution's ph value is within error range.
7.The calibration of the instrumen's pH range is now complete.
2)ORP
1. Turn on the meter.Press the"pH/ORP" button,choice the ORP for measuring.
2. Rinse the electrode with distilled water.
3. Immerse the electrode into the fresh 256mV ORP standard solution,then stir it gently,
4. Allow the reading to stabilize and with a small screwdriver turn the calibration trimmer until the display shows"256".
5. Rinse the electrode with distilled water and suck it with filter paper.
6. Switch off the meter.Replace the battery compartment cap.
The calibration of the instrument's ORP range is now complete.
- Semua produk kami bergaransi distributor Jakarta
---
Alat pengukur air 3 in 1:
1. ORP - Potensial Pengurangan Oksidasi
2. PH - Kadar Asam Basa, dan
3. Temperature - Suhu Air
Specifications:
Measuring range:
PH: 0.00-14.00pH
ORP:-1999-1999mV
Temp:0-50℃
Resolution:
PH:0.01pH
ORP:1mV
Temp:0.1℃
Acuracy:
PH:±0.1pH
ORP:±5mV
Temp:±1℃
Automatic Temperature Compensation.O℃~50℃
Batery Type:4×1.5V(AG13)
Operating Temperature:0℃~50℃
Calibration:Manual.at one point through trimmer
Dimensions:188mm×35mm×35mm
Weight: 98g
Dikirim dari Jakarta,
bergaransi distributor Jakarta
How to Calibrate
1)PH
1.Rinse the ph electrode first with distilled water,and suck it with filter paper.
2.Turn on the meter. Press the "pH/ORP"button,choice the PH for measuring.
3.Immerse the ph electrode in pH6.86(or pH7.00)buffer solution,gently shake the meter and wait for a stable display.
4.Regulate the trimmer with the screwdriver provided until display shows "6.86"("7.00")at buffer solution temperature of 25℃.
5.Rinse the ph electrode with distilled water,and suck it with filter paper (not included)
6.Immerse the pH electrode in pH4.01 or pH9.18(pH10.0)buffer solution,gently shake the electrode and waiting for the reading to stabilize.The showing value and buffer solution's ph value is within error range.
7.The calibration of the instrumen's pH range is now complete.
2)ORP
1. Turn on the meter.Press the"pH/ORP" button,choice the ORP for measuring.
2. Rinse the electrode with distilled water.
3. Immerse the electrode into the fresh 256mV ORP standard solution,then stir it gently,
4. Allow the reading to stabilize and with a small screwdriver turn the calibration trimmer until the display shows"256".
5. Rinse the electrode with distilled water and suck it with filter paper.
6. Switch off the meter.Replace the battery compartment cap.
The calibration of the instrument's ORP range is now complete.

HRDIK
• Online4.7rating toko
± 12 jampesanan diproses
Penawaran Lainnya
Paylater & Cicilan
mulai Rp92.780, tersedia bunga 0%.
Harga Grosir
Lebih murah, mulai dari Rp829.000 min. 3 pcs
Jumlah | Harga Satuan |
≥ 3 | Rp829.000 |
Ada masalah dengan produk ini?
Ulasan(3)
ORP PH Temperature Meter 3 in 1 ORP-3569 Tester Water ORP3569 Kangen