Atur jumlah dan catatan
Stok Total: 287
Subtotal
Rp1.136.000
TONGOU Din Rail 2P 4P ATS Dual Power Automatic Transfer Switch Electrical Selector Switches Uninterrupted Power 110V 220V 63A
Rp1.136.000
- Kondisi: Baru
- Waktu Preorder: 30 Hari
- Min. Pemesanan: 1 Buah
- Etalase: Semua Etalase
SELAMAT DATANG DI TOKO KAMI
Brand Name : TONGOU
Model Number : TOATS-2
Type : Mini
Origin : Mainland China
Certification : CE
Rated Voltage : 220V
is_customized : Yes
Is Smart Device : no
Hign-concerned Chemical : None
Switching Speed : <50 milliseconds
Pleasenote:
that this product is not suitable for photovoltaic applications
City Power Generator
BEST ATS QUALITY IN ALIEXPRESS---SILVER CONTACT POINT & RED COPPER PARTS & STABLE RELAY CONTROL
General
TOATS-2 automatic transfer switch is a PC class infrequent change-over switch, with two-station design (commonly used for A and standby for B), suitable for AC systems with AC 50-60hz and rated current 6A-63A. The main function of the automatic transfer switch is when the main power (common power supply A) fails, the ATS will automatically switch to the backup power (Backup power supply B) to continue working (switching speed <50 milliseconds), which can effectively solve the troubles caused by power outages.
When both A and B have electricity, priority is using A Power
NOTE:
1. Manual/automatic operation can ensure the opening and closing performance of electrical operation, but in manual operation , there is no guarantee due to the different _opening/closing speeds of the operators. In manual operation, there's possible for excessive silver alloy loss . Therefore, the selector switch should only be pulled to the manual position after all power has been cut off for inspection and maintenance of the operating system and contact information.
2, Normally, pull the selector switch to the electric position. When manual operation is required, pull the selector switch to the manual position. After manual operation is complete, pull the selector switch from the manual position to the automatic position.
The control circuit TSE is immediately energized. After the change over is completed, the internal switch will damage the coil in the control circuit, and the coil can work normally at 85 of the rated operating voltage. Too low input voltage may cause the coil to overheat and burn out.
Attention!When manual operation the mode selection switch must be in "manual" position
Sebelum membeli suatu produk, Mohon dapat membaca deskripsi produk dengan cermat
Harap tanyakan stok sebelum melakukan pemesanan ya kak
Jika Anda memiliki pertanyaan, silakan hubungi kami.
Brand Name : TONGOU
Model Number : TOATS-2
Type : Mini
Origin : Mainland China
Certification : CE
Rated Voltage : 220V
is_customized : Yes
Is Smart Device : no
Hign-concerned Chemical : None
Switching Speed : <50 milliseconds
Pleasenote:
that this product is not suitable for photovoltaic applications
City Power Generator
BEST ATS QUALITY IN ALIEXPRESS---SILVER CONTACT POINT & RED COPPER PARTS & STABLE RELAY CONTROL
General
TOATS-2 automatic transfer switch is a PC class infrequent change-over switch, with two-station design (commonly used for A and standby for B), suitable for AC systems with AC 50-60hz and rated current 6A-63A. The main function of the automatic transfer switch is when the main power (common power supply A) fails, the ATS will automatically switch to the backup power (Backup power supply B) to continue working (switching speed <50 milliseconds), which can effectively solve the troubles caused by power outages.
When both A and B have electricity, priority is using A Power
NOTE:
1. Manual/automatic operation can ensure the opening and closing performance of electrical operation, but in manual operation , there is no guarantee due to the different _opening/closing speeds of the operators. In manual operation, there's possible for excessive silver alloy loss . Therefore, the selector switch should only be pulled to the manual position after all power has been cut off for inspection and maintenance of the operating system and contact information.
2, Normally, pull the selector switch to the electric position. When manual operation is required, pull the selector switch to the manual position. After manual operation is complete, pull the selector switch from the manual position to the automatic position.
The control circuit TSE is immediately energized. After the change over is completed, the internal switch will damage the coil in the control circuit, and the coil can work normally at 85 of the rated operating voltage. Too low input voltage may cause the coil to overheat and burn out.
Attention!When manual operation the mode selection switch must be in "manual" position
Sebelum membeli suatu produk, Mohon dapat membaca deskripsi produk dengan cermat
Harap tanyakan stok sebelum melakukan pemesanan ya kak
Jika Anda memiliki pertanyaan, silakan hubungi kami.
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan