    Specifications
    OPERATIONAL SPECIFICATIONS
    Protection range: 16 to 230 feet (5 to 70 m), 230 to 328 feet
    (70 to 100 m) using optional BEAMLRK kit.
    Adjustment angle: ±10° horizontal and vertical. Note that the
    optics move independently of the unit.
    Sensitivity (6 levels):
    • Level 1 — 25%.
    • Level 2 — 30%.
    • Level 3 — 40%.
    • Level 4 — 50%.
    • Acclimate Level 5 — 30% to 50%.
    • Acclimate Level 6 — 40% to 50%.
    Fault condition (trouble):
    • 96% or more obscuration blockage.
    • In alignment mode.
    • Improper initial alignment.
    • Self-compensation limit reached.
    Alignment aid:
    • Optical gunsight.
    • Integral signal strength indication.
    • Two-digit display.
    Indicators:
    • Alarm — local red LED and remote alarm.
    • Trouble — local yellow LED and remote trouble.
    • Normal — local flashing green LED.
    Test/reset features:
    Integral sensitivity test filter (BEAM1224S only, requires external power supply).
    • Sensitivity filter (incremental scale on reflector).
    • Local alarm test switch.
    • Local alarm reset switch.
    • Remote test and reset switch (compatible with RTS151 and
    RTS151KEY test stations).
    Smoke detector spacing: On smooth ceilings, 30 – 60 feet
    (9.1 to 18.3 m) between projected beams and not more than
    one-half that spacing between a projected beam and a sidewall. Other spacing may be used depending on ceiling height,
    airflow characteristics, and response requirements. See NFPA
    72.
    ENVIRONMENTAL SPECIFICATIONS
    Temperature: –22°F to 131°F (–30°C to 55°C).
    Humidity: 10 – 93% RH noncondensing.
    ELECTRICAL SPECIFICATIONS
    Voltage: 10.2 to 32 VDC (BEAM1224); 15 to 32 VDC
    (BEAM1224S).
    Standby current (24 VDC): 17 mA maximum.
    Alarm current (24 VDC): 38.5 mA maximum.
    Alignment mode current (24 VDC): 28 mA maximum.
    Test mode current (BEAM1224S only): 500 mA maximum @
    peak test.
    Relay contacts: 0.5 A @ 30 VDC.
    Reset time: 0.3 seconds maximum.
    Start-up time (after 2 min. reset): 60 seconds max.