General Specifications Maximum voltage between any terminal and earth ground 600 V Safety IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Specifications DC millivolts Range/resolution 600.0 mV / 0.1 mV Accuracy ± ([% of reading] + [counts]): 0.5% + 2 DC volts Range/resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V Accuracy ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) AC volts1 True RMS Range/resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 Ω / 1 Ω Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.