FEATURES Innovative sensor design minimizes measurement variations caused by device angle or contact pressure Consistent data quality at both low and high frequency ranges Four-level severity scale assesses urgency of problems for overall vibration and bearing condition Exportable data via USB Trending in Microsoft Excel using pre-built templates Overall vibration measurement (10 Hz to 1,000 Hz) for acceleration, velocity and displacement units of measurement for a wide variety of machines Crest Factor+ technology provides reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz Compare vibration levels with ISO-10816 severity scales and store results to the Fluke Connect Cloud Get authorization to take next steps in an instant if machine health is at risk via Fluke Connect Share-Live video call* Colored lighting system (green, red) and on-screen comments indicate how much pressure needs to be applied to take measurements Temperature measurement with Spot IR Sensor increases diagnostic capabilities On-board memory holds and saves up to 3,500 measurements External accelerometer support for hard to reach locations Flashlight for viewing measurement locations in dark areas Large screen with high resolution for easy navigation and viewing SPECIFICATIONS: Sensitivity (typical): 100 mV / g ±10 % Measurement Range: 0.01 g to 50 g Frequency Range: 10 Hz to 1,000 Hz and 4,000 Hz to 20,000 Hz Resolution: 0.01 g Accuracy (typical)at 100 Hz: ±5 % of measured value Amplitude Units Acceleration: g, m/sec2 Velocity: in/sec, mm/sec Displacement: mils, μm See Fluke 805FC specs