Atur jumlah dan catatan
Stok Total: Sisa 2
Subtotal
Rp4.117.000
EZC400H3400N circuit breaker Easypact EZC400H - TMD - 400 A - 3 poles
Rp4.117.000
range of product:EasyPact
product or component type:Circuit breaker
device short name:Easypact EZC400H
circuit breaker name:Easypact EZC400H
device application:Distribution
poles description:3P
protected poles description:3t
network type:DC
AC
network frequency:50/60 Hz
In rated current:400 A at 40 C
Ui rated insulation voltage:690 V AC 50/60 Hz conforming to IEC 60947-2
Uimp rated impulse withstand voltage:6 kV conforming to IEC 60947-2
Ue rated operational voltage:250 V DC conforming to IEC 60947-2
440 V AC 50/60 Hz conforming to IEC 60947-2
breaking capacity code:H
breaking capacity:50 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Ics rated service breaking capacity:25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation:Yes conforming to IEC 60947-2
utilisation category:Category A
trip unit name:TM-D
trip unit technology:Thermal-magnetic
trip unit rating:400 A at 50 C
protection type:Short-circuit protection
Overload protection
pollution degree:3 conforming to IEC 60947
control type:Toggle
mounting mode:Fixed
mounting support:Backplate
upside connection:Front
downside connection:Front
mechanical durability:10000 cycles
electrical durability:Category A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
connection pitch:45 mm
local signalling:Positive contact indication
contact position indicator:Yes
magnetic tripping current:4000 A
neutral protection setting:Without protection
long time pick-up adjustment type Ir:Fixed
long time delay adjustment type:Fixed
earth-leakage protection:Without
height:25
product or component type:Circuit breaker
device short name:Easypact EZC400H
circuit breaker name:Easypact EZC400H
device application:Distribution
poles description:3P
protected poles description:3t
network type:DC
AC
network frequency:50/60 Hz
In rated current:400 A at 40 C
Ui rated insulation voltage:690 V AC 50/60 Hz conforming to IEC 60947-2
Uimp rated impulse withstand voltage:6 kV conforming to IEC 60947-2
Ue rated operational voltage:250 V DC conforming to IEC 60947-2
440 V AC 50/60 Hz conforming to IEC 60947-2
breaking capacity code:H
breaking capacity:50 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Ics rated service breaking capacity:25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation:Yes conforming to IEC 60947-2
utilisation category:Category A
trip unit name:TM-D
trip unit technology:Thermal-magnetic
trip unit rating:400 A at 50 C
protection type:Short-circuit protection
Overload protection
pollution degree:3 conforming to IEC 60947
control type:Toggle
mounting mode:Fixed
mounting support:Backplate
upside connection:Front
downside connection:Front
mechanical durability:10000 cycles
electrical durability:Category A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
connection pitch:45 mm
local signalling:Positive contact indication
contact position indicator:Yes
magnetic tripping current:4000 A
neutral protection setting:Without protection
long time pick-up adjustment type Ir:Fixed
long time delay adjustment type:Fixed
earth-leakage protection:Without
height:25