range of product:Zelio Logic
product or component type:Modular smart relay
local display:With
number or control scheme lines:0...500 with FBD programming
0...240 with ladder programming
cycle time:6...90 ms
backup time:10 years at 25 °C
clock drift:12 min/year at 0...55 °C
6 s/month at 25 °C
checks:Program memory on each power up
Us rated supply voltage:24 V
supply voltage limits:19.2...30 V
maximum supply current:180 mA (with extensions)
70 mA (without extension)
power dissipation in W:10 W with extensions
5 W without extension
reverse polarity protection:With
discrete input number:16 conforming to EN/IEC 61131-2 type 1
discrete input type:Resistive
discrete input voltage:24 V DC
discrete input current:4 mA
counting frequency:1 kHz for discrete input
voltage state 1 guaranteed:>= 15 V for I1...IA and IH...IR discrete input circuit
>= 15 V for IB...IG used as discrete input circuit
voltage state 0 guaranteed:<= 5 V for I1...IA and IH...IR discrete input circuit
<= 5 V for IB...IG used as discrete input circuit
current state 1 guaranteed:>= 1.2 mA (IB...IG used as discrete input circuit)
>= 2.2 mA (I1...IA and IH...IR discrete input circuit)
current state 0 guaranteed:<= 0.5 mA (IB...IG used as discrete input circuit)
<= 0.75 mA (I1...IA and IH...IR discrete input circuit)
input compatibility:3-wire proximity sensors PNP for discrete input
analogue input number:6
analogue input type:Common mode
analogue input range:0...24 V
0...10 V
temperature probe type:NTC 10k at 25 °C
NTC 1000k at 25 °C
KTY81 210/220/221/222/250
Pt 500
maximum permissible voltage:30 V for analogue input circuit
analogue input resolution:8 bits
LSB value:39 mV for analogue input circuit
conversion time:Smart relay cycle time for analogue input circuit
conversion error:+/- 5 % at 25 °C for analogue input circuit
+/- 6.2 % at 55 °C for analogue input circuit
repeat accuracy:+/- 2 % at 55 °C for analogue input circuit
operating distance:10 m between stations, with screened cable (sensor not isolated)