Atur jumlah dan catatan
Stok Total: 100
Subtotal
Rp5.126.300
PLC industrial control board Delta DVP48EC00T3 Transistor module 28DI 20DO 100-240VAC Controller in box
Rp5.126.300
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: Semua Etalase
PLC industrial control board Delta DVP48EC00T3 Transistor module 28DI 20DO 100-240VAC Controller in box
ā³ Pre-Order +/- Sampai Alamat 15-20 Harian
Oscilloscope Parts & Accessories Type : Oscilloscope Parts
Model : DVP48EC00T3
Electrical Specifications
Model
Item
10EC
00
_
3
14
EC
00
_
3
16
EC
00
_
3
20
EC
00
_
3
24
EC
00
_
3
30
EC
00
_
3
32
EC
00
_
3
40
EC
00
_
3
48
EC
00
_
3
60
EC
00
_
3
Power supply voltage
100 ~ 240VAC (-15), 50/60Hz + - 5%
Operation
DVP-EC3 starts to run when the power supply rises to 95 ~ 100V AC and
stops when the power supply drops to 70V AC. It continues to run for 10ms
after the power supply is cut off.
Power supply fuse
2A/250VAC
Power consumption
12VA
15.6VA
22.5VA
DC24V current output
200mA
300mA
400mA
Power supply
DC24V output short circuit
Voltage withstand
1,500VAC (Primary-secondary), 1,500VAC (Primary-PE), 500VAC
(Secondary-PE)
Insulation resistance
> 5M at 500VDC (between all I/O points and earth)
Noise immunity
ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge
EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV, Analog
& Communication I/O: 1kV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
Grounding
The diameter of grounding wire shall not be less than that of L, N terminal of
the power supply. (When many PLCs are in use at the same time, please
make sure every PLC is properly grounded.)
Operation/storage
Operation: 0 C ~55 C (temperature), 50~95% (humidity), pollution degree 2
Storage: -25 C ~70 C (temperature), 5~95% (humidity)
Agency approvals
UL508
European community EMC Directive 89/336/EEC and Low Voltage Directive
73/23/EEC
Vibration/shock immunity
Internat
ā³ Pre-Order +/- Sampai Alamat 15-20 Harian
Oscilloscope Parts & Accessories Type : Oscilloscope Parts
Model : DVP48EC00T3
Electrical Specifications
Model
Item
10EC
00
_
3
14
EC
00
_
3
16
EC
00
_
3
20
EC
00
_
3
24
EC
00
_
3
30
EC
00
_
3
32
EC
00
_
3
40
EC
00
_
3
48
EC
00
_
3
60
EC
00
_
3
Power supply voltage
100 ~ 240VAC (-15), 50/60Hz + - 5%
Operation
DVP-EC3 starts to run when the power supply rises to 95 ~ 100V AC and
stops when the power supply drops to 70V AC. It continues to run for 10ms
after the power supply is cut off.
Power supply fuse
2A/250VAC
Power consumption
12VA
15.6VA
22.5VA
DC24V current output
200mA
300mA
400mA
Power supply
DC24V output short circuit
Voltage withstand
1,500VAC (Primary-secondary), 1,500VAC (Primary-PE), 500VAC
(Secondary-PE)
Insulation resistance
> 5M at 500VDC (between all I/O points and earth)
Noise immunity
ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge
EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV, Analog
& Communication I/O: 1kV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
Grounding
The diameter of grounding wire shall not be less than that of L, N terminal of
the power supply. (When many PLCs are in use at the same time, please
make sure every PLC is properly grounded.)
Operation/storage
Operation: 0 C ~55 C (temperature), 50~95% (humidity), pollution degree 2
Storage: -25 C ~70 C (temperature), 5~95% (humidity)
Agency approvals
UL508
European community EMC Directive 89/336/EEC and Low Voltage Directive
73/23/EEC
Vibration/shock immunity
Internat
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan