Specifications: Product Model:XY-L10A Control voltage:DC6-60V Control current:<10A Control accuracy:0.1V Output Type: Direct Output Voltage error:±0.1V Scope of application: various lithium batteries
First.Function description
1.Automatic Charge control function:
By setting the volt-HI:‘UP\' volt-LI:‘dn\';When the battery voltage is below the volt-LI:\'dn\',the relay leads,the charger begins to charge the battery;when the battery voltage is up to volt-HI:\'UP\',the relay is diconnected and the automatic charge is completed once
2.Charge Time Control Function:
How to turn on the time control function?
After entering the parameter set, set the parameter op is non-zero, then turn on the time control function, op default parameter is:--:--h, the default does not turn on time control function;
After the opening Time control function (OP is non-zero), when the battery voltage is the lower volt-LI\'dn\', the charger began to charge the battery, the system began to clock; During the timing, the battery voltage ≥ volt-HI\'UP\', relay disconnect; If the OP time is up, the battery voltage is still the lower volt-LI\'dn\', the relay keeps the conduction, automatically closes the charge time control function, and flashes the H:ER to remind the user, the time parameter setting is unreasonable; Press any key to stop flashing;
Note: Time format: 00:59 (00 for hours, 59 for minutes) The maximum time is 99:59, which is 100 hours.
Second.Parameter Setting
a)Press and hold the SET key to enter the setting interface;
b)Switch the parameters you want to set by short press SET;
c)After the selection of parameters, can be set by the UP/DOWN key to support the short press, long press (fast increase or decrease); To set other parameters, repeat step b, c);
d)After all parameters are set, long press set key to exit and save;