Download Tokopedia App
Tentang TokopediaMulai Berjualan PromoTokopedia Care
tokopedia-logo
Kategori
Atur jumlah dan catatan

Stok Total: Sisa 5

Subtotal

Rp37.240.000

ABB Softstarter PSTX105-600-70 Soft starter 105A 55KW 1SFA898109R7000

Rp37.240.000
    Softstarter PSTX105-600-70
    Rated Operational Voltage:
    208 ... 600 V AC
    Rated Control Supply Voltage (Us):
    100 ... 250 V AC
    Rated Control Circuit Voltage (Uc):
    24 V DC
    Rated Frequency (f):
    50/60 Hz
    Main Circuit 50 / 60 Hz
    Rated Operational Power - In-Line Connection (Pe):
    (230 V) 30 kW
    (400 V) 55 kW
    (500 V) 75 kW
    Rated Operational Current - In-Line Connection (Ie):
    105 A
    Rated Operational Power - Inside Delta Connection:
    at 230 V 55 kW
    at 400 V 90 kW
    at 500 V 110 kW
    Rated Operational Current - Inside Delta Connection:
    181 A
    Service Factor Percentage:
    100 %
    Overload Protection:
    Built-in electronic overload protection
    Integrated Electronic Overload:
    Yes
    Starting Capacity at Maximum Rated Current Ie:
    4xIe for 10s
    Ramp Time:
    1 ... 120 second [unit of time]
    Initial Voltage During Start:
    10 ... 99 %
    Step Down Voltage Special Ramp:
    100 ... 10 %
    Current Limit Function:
    1.5 ... 7.5 xle
    Switch for Inside Delta Connection:
    Yes
    Run Signal Relay:
    Yes
    By-pass Signal Relay:
    Yes
    Fault Signal Relay:
    Yes
    Overload Signal Relay:
    Yes
    Analog Outputs:
    0…10 V, 0…20 mA, 4…20 mA
    Signal Indication Ready to Start/Standby ON (LED):
    Green
    Signal Indication Running R (LED):
    Green
    Signal Indication Protection (LED):
    Yellow
    Signal Indication Fault (LED):
    Red
    Communication:
    Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
    Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
    Terminal Type:
    Cable Clamp
    Connecting Capacity Main Circuit:
    Hole Diameter 8.5 mm
    Connecting Capacity Control Circuit:
    Rigid 1 x 2.5 mm²
    Connecting Capacity Supply Circuit:
    Rigid 1 x 2.5
    Tightening Torque:
    Main Circuit 8 N·m
    Product Main Type:
    PSTX105
    Function:
    Auto phase sequence detection
    Automatic restart
    Current limit
    Current limit ramp
    Dual current limit
    Dynamic brake
    Electricity metering
    Electronic overload Time-to-cool
    Emergency mode
    Event log
    Full voltage start
    Jog with slow speed, forward and reverse
    Keypad password
    Kick start
    Limp mode with two-phase motor control if one set of thyristors is shorted
    Motor heating
    Pre-start function
    Pump cleaning
    Real time clock
    Sequence start
    Soft start with torque control
    Soft start with voltage ramp
    Soft stop with torque control
    Soft stop with voltage ramp
    Stand still brake
    Start reverse (external contactors)
    Thyristor runtime measurement
    Torque limit
    Voltage sags detection
    Show less
    Protection Function:
    Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
    Warning Details:
    Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
    Ada masalah dengan produk ini?

    ULASAN PEMBELI

    5.0/ 5.0

    100% pembeli merasa puas

    2 rating • 2 ulasan

    5(2)100%
    4(0)0%
    3(0)0%
    2(0)0%
    1(0)0%