Atur jumlah dan catatan
Stok Total: Sisa 2
Subtotal
Rp1.600.000
Inductance Decade Box Lutron LBOX-405
Rp1.600.000
- Kondisi: Baru
- Waktu Preorder: 30 Hari
- Min. Pemesanan: 1 Buah
- Etalase: Alat Ukur Listrik
Decade Inductance Box Lutron LBOX-406
Made in Taiwan
* Applications :
General applications
Troubleshooting, maintenance
Education and Vocational training
Production line testing
Radio and TV services
Working standards
Research design & develop
Physics laboratory work
* Pocket size, offering accurate, reliable performance.
* 10 uH to 111.1 mH, wide range and high resolution ( 10 uH per step ), practical and versatile tools.
* With four decades of inductance.
* Slide switches that allow the user to simply add or subtract for desired value.
* Terminals with multi way binding posts, one to switch shield case.
* ABS plastic housing case, rugged components.
SPECIFICATIONS
Range 10 uH to 111.1 mH ( 10 uH per step )
Accuracy 5% inductors used throughout.
@ 23 5
@ 1 KHz test frequency
Max. 10 mA DC or AC.
Rating
Current
Internal Approx. 0.5 uH.
Residual
Inductance
Power Supply None.
Operating 0 to 50 (32 to 122 ).
Temperature
Operating Less than 80% RH.
Humidity
Weight 333 g/0.74 lb.
Dimension 14.7 cm x 11.7 cm x 5.5 cm.
( 5.79 x 4.61 x 2.16 inch ).
Accessory IncludedOperation Manual...................................................... .1.. .P..C.
Testing Procedure
1) Start with all switches up ( OUT ) for min. inductance.
2) Switch down ( IN ) to add Inductance value.
3) The " Ground Terminal " is connected to the metal enclosure of all switches For some
special application may connect the " Ground Terminal " to the external equipment to
prevent other environment interference.
Made in Taiwan
* Applications :
General applications
Troubleshooting, maintenance
Education and Vocational training
Production line testing
Radio and TV services
Working standards
Research design & develop
Physics laboratory work
* Pocket size, offering accurate, reliable performance.
* 10 uH to 111.1 mH, wide range and high resolution ( 10 uH per step ), practical and versatile tools.
* With four decades of inductance.
* Slide switches that allow the user to simply add or subtract for desired value.
* Terminals with multi way binding posts, one to switch shield case.
* ABS plastic housing case, rugged components.
SPECIFICATIONS
Range 10 uH to 111.1 mH ( 10 uH per step )
Accuracy 5% inductors used throughout.
@ 23 5
@ 1 KHz test frequency
Max. 10 mA DC or AC.
Rating
Current
Internal Approx. 0.5 uH.
Residual
Inductance
Power Supply None.
Operating 0 to 50 (32 to 122 ).
Temperature
Operating Less than 80% RH.
Humidity
Weight 333 g/0.74 lb.
Dimension 14.7 cm x 11.7 cm x 5.5 cm.
( 5.79 x 4.61 x 2.16 inch ).
Accessory IncludedOperation Manual...................................................... .1.. .P..C.
Testing Procedure
1) Start with all switches up ( OUT ) for min. inductance.
2) Switch down ( IN ) to add Inductance value.
3) The " Ground Terminal " is connected to the metal enclosure of all switches For some
special application may connect the " Ground Terminal " to the external equipment to
prevent other environment interference.
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan