Key Features
• Easily get into tight spaces between cables thanks to thin sensor structure
• Measure up to 1000 A
• Automatic AC/DC function helps boost work efficiency
• Measure DC voltages of up to 1700 V (*1)
• Simultaneously measure inrush current in RMS and crest values
• Expanded -25 °C to 65 °C operating temperature range
• 3 year guarantee
DC Current range 1000 A, (Max. display 999.9 A) , Basic accuracy: ±1.3% rdg. ±0.3 A (at 30.1 A - 999.9 A)
AC Current range 1000 A (Max. display 999.9 A, 10 Hz to 1 kHz, True RMS), Basic accuracy 45-66 Hz: ±1.3% rdg. ±0.3 A (at 30.1 A - 900.0 A)
Crest factor 1.5
DC+AC Current range 1000 A (DC, 10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±1.3 A (at 30.1 A - 900.0 A)
DC Power range 0.0 VA to 1700 kVA (Automatically switched based on voltage range), Basic accuracy: ±2.0% rdg. ±20 dgt.
DC Voltage range 600.0 mV to 1500 V (*1), 5 ranges, Basic accuracy: ±0.5% rdg. ±0.5 mV (at 600 mV)
AC Voltage range 6.000 V to 1000 V, 5 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.013 V (at 6 V)
DC+AC Voltage range 6.000 V to 1000 V, 5 ranges, Basic accuracy DC, 45-66 Hz: ±1.0% rdg. ±0.023 V (at 6 V)
Resistance range 600.0 Ω to 600.0 kΩ, 4 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Electrostatic capacity range 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency range 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
Other functions Automatic AC/ DC detection, DC current and DC voltage polarity detection function, MAX/ MIN/ AVG/ PEAK MAX/ PEAK MIN value display, Low-pass filter function, Display value hold, Auto hold, Backlight, Auto power save, Buzzer sound, Zero-adjustment
Included accessories Test Lead L9300, Carrying Case C0203, LR03 Alkaline battery ×2, Instruction Manual ×2, Operating Precautions ×1