FEATURES
Dissolved Oxygen Probe:
1. Galvanic probe, no need polarization time
2. Filling solution and membrane cap is replaceable, low maintenance cost
Signal Converter Board:
1. 3.3~5.5V wide-range power supply, compatible with most Arduino microcontroller
2. 0~3.0V analog output, compatible with all microcontrollers with ADC function.
3. Gravity interface, plug, and play, easy to use
SPECIFICATION :
☞ Dissolved oxygen sensor for Arduino TECH SPECS
☞ Dissolved Oxygen Probe
☞ Type: Galvanic Probe
☞ Detection Range: 0~20mg/L
☞ Response Time: Up to 98% full response, within 90 seconds (25℃)
☞ Pressure Range: 0~50PSI
☞ Electrode Service Life: 1 year (normal use)
☞ Maintenance Period: Membrane Cap Replacement Period: 1~2 months (in muddy water); 4~5 months - (in clean water) Filling Solution Replacement Period: Once every month
☞ Cable Length: 2 meters
☞ Probe Connector: BNC
☞ Signal Converter Board
☞ Operating Voltage: 3.3~5.5V
☞ Output Signal: 0~3.0V
☞ Cable Connector: BNC
☞ Signal Connector: Gravity Analog Interface (PH2.0-3P)
☞ Dimension: 42mm * 32mm
SHIPPING LIST :
☞ Galvanic Dissolved Oxygen Probe with Membrane Cap x1
☞ Spare Membrane Cap x1
☞ Signal Converter Board x1
☞ Gravity Analog Sensor Cable x1
☞ Waterproof Gasket x2
☞ Screw Cap for BNC Connector x1
☞ Plastic Dropper x2
DOCUMENTS
☞ https://wiki.dfrobot.com/Gravity__Analog_Dissolved_Oxygen_Sensor_SKU_SEN0237
Dissolved Oxygen Probe:
1. Galvanic probe, no need polarization time
2. Filling solution and membrane cap is replaceable, low maintenance cost
Signal Converter Board:
1. 3.3~5.5V wide-range power supply, compatible with most Arduino microcontroller
2. 0~3.0V analog output, compatible with all microcontrollers with ADC function.
3. Gravity interface, plug, and play, easy to use
SPECIFICATION :
☞ Dissolved oxygen sensor for Arduino TECH SPECS
☞ Dissolved Oxygen Probe
☞ Type: Galvanic Probe
☞ Detection Range: 0~20mg/L
☞ Response Time: Up to 98% full response, within 90 seconds (25℃)
☞ Pressure Range: 0~50PSI
☞ Electrode Service Life: 1 year (normal use)
☞ Maintenance Period: Membrane Cap Replacement Period: 1~2 months (in muddy water); 4~5 months - (in clean water) Filling Solution Replacement Period: Once every month
☞ Cable Length: 2 meters
☞ Probe Connector: BNC
☞ Signal Converter Board
☞ Operating Voltage: 3.3~5.5V
☞ Output Signal: 0~3.0V
☞ Cable Connector: BNC
☞ Signal Connector: Gravity Analog Interface (PH2.0-3P)
☞ Dimension: 42mm * 32mm
SHIPPING LIST :
☞ Galvanic Dissolved Oxygen Probe with Membrane Cap x1
☞ Spare Membrane Cap x1
☞ Signal Converter Board x1
☞ Gravity Analog Sensor Cable x1
☞ Waterproof Gasket x2
☞ Screw Cap for BNC Connector x1
☞ Plastic Dropper x2
DOCUMENTS