Fluke319 are True RMS Clamp meter designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments. Fluke 319 also offer AC/DC current measurements and has a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, the Fluke 319 also equip with In-rush current and Frequency functions for testing motors, lighting, etc.
specifications
Current AC Range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ±6 digit (50-60 Hz) {40 A}
2.5% ±8 digit (60-500 Hz) {40 A}
1.5% ±5 digit (50-60 Hz) {600/1000 A}
2.5% ±5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response rms
Current DC Range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ±6 digit (40 A)
1.5% ±5 digit (600/1000 A)
Voltage AC Range 600.0 V
Resolution 0.1 V
Accuracy 1.5% ±5 digit (20-500Hz)
AC response rms
Voltage DC Range 600.0 V
Resolution 0.1 V
Accuracy 1% ±4 digit
Resistance Range 400.0 Ω
4000 Ω
Resolution 0.1 Ω
1 Ω
Accuracy 1% ±5 digit
Continuity ≤ 30 Ω
Inrush Integration time 100 ms
Frequency Range 5.0 - 500.0 Hz
Accuracy 0.5% ±5 digit
(Catatan;pengukuran Frequency baru bisa terbaca di alat, jika beban arus listrik yang sedang digunakan diatas 0,5 Ampere ,
Dibawah 0,5 Ampere, Frequency listrik tidak terbaca)
Trigger Level 10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A
Accessories included ( termasuk ) :
* Test Leads
* Soft Carrying Case
* User Manual
* Batere AAA (1,5V) 3 pcs
specifications
Current AC Range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ±6 digit (50-60 Hz) {40 A}
2.5% ±8 digit (60-500 Hz) {40 A}
1.5% ±5 digit (50-60 Hz) {600/1000 A}
2.5% ±5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response rms
Current DC Range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% ±6 digit (40 A)
1.5% ±5 digit (600/1000 A)
Voltage AC Range 600.0 V
Resolution 0.1 V
Accuracy 1.5% ±5 digit (20-500Hz)
AC response rms
Voltage DC Range 600.0 V
Resolution 0.1 V
Accuracy 1% ±4 digit
Resistance Range 400.0 Ω
4000 Ω
Resolution 0.1 Ω
1 Ω
Accuracy 1% ±5 digit
Continuity ≤ 30 Ω
Inrush Integration time 100 ms
Frequency Range 5.0 - 500.0 Hz
Accuracy 0.5% ±5 digit
(Catatan;pengukuran Frequency baru bisa terbaca di alat, jika beban arus listrik yang sedang digunakan diatas 0,5 Ampere ,
Dibawah 0,5 Ampere, Frequency listrik tidak terbaca)
Trigger Level 10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A
Accessories included ( termasuk ) :
* Test Leads
* Soft Carrying Case
* User Manual
* Batere AAA (1,5V) 3 pcs