Download Tokopedia App
Tentang TokopediaMulai Berjualan PromoTokopedia Care
tokopedia-logo
Kategori
Atur jumlah dan catatan

Stok Total: Sisa 10

Subtotal

Rp97.000.000

Kyoritsu 3128 Digital High Insulation Tester Megger 12 KV

Rp97.000.000
    Test Voltage 12kV (max), Resistance 35TΩ (max)
    Short-Circuit Current 5mA (max)
    Graphic representation of the insulation resistance and leakage current versus time on large display with bar graph and backlight
    Print Screen Function enables to record up to 32 display screens
    Internal Memory can store about 43,000 data (max)
    Can be operated from internal rechargeable battery or from AC line
    Robust design for field use with IP64 rating (with lid closed)

    Specification :
    Insulation resistance
    Test voltage 500V 1000V 2500V 5000V 10000V 12000V
    Max measurement value 500GΩ 1TΩ 2.5TΩ 5TΩ 35TΩ
    Accuracy 400kΩ - 50GΩ
    ±5%rdg±3dgt 800kΩ - 100GΩ
    ±5%rdg±3dgt 2MΩ - 250GΩ
    ±5%rdg±3dgt 4MΩ - 500GΩ
    ±5%rdg±3dgt 8MΩ - 1TΩ
    ±5%rdg±3dgt
    50.1 - 500GΩ
    ±20%rdg(*) 101G - 1TΩ
    ±20%rdg 251G - 2.5TΩ
    ±20%rdg 501GΩ - 5TΩ
    ±20%rdg 1.01 - 10TΩ
    ±20%rdg
    10.1 - 35TΩ
    Short circuit current Max 5.0mA
    Load resistor to output rated voltage 0.5MΩ or more 1MΩ or more 2.5MΩ or more 5MΩ or more 20MΩ or more 24MΩ or more
    Output voltage
    Rated voltage 500V 1000V 2500V 5000V 10000V 12000V
    Monitor accuracy
    ±10%±20V
    Output accuracy
    0 - +20% 0 - +10% -5 - +5%
    Selectable range
    50 - 600V
    (in steps of 5V) 610 - 1200V
    (in steps of 10V) 1225 - 3000V
    (in steps of 25V) 3050 - 6000V
    (in steps of 50V) 6100 - 10000V
    (in steps of 100V) 10100 - 12000V
    (in steps of 100V)
    Voltage measurement
    Measuring range DCV:±30 ~ ±600V
    ACV:30 ~ 600V (50/60Hz)
    Accuracy ±2%rdg±3dgt
    Current measurement
    Measuring range 5.00nA - 2.40mA
    (Depending on the insulation resistance)
    Accuracy ±5%rdg±5dgt
    Capactince measurement
    Measuring range 5.0nF - 50.0μF 40.0nF - 1.00μF
    (Display range : 5.0nF - 60.0μF)
    Accuracy ±5%rdg±5dgt
    General
    Applicable standards IEC 61010-1 CAT IV 600V Pollution degree 2, IEC 61010-2-034,
    IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed.
    Operating temperature and humidity range -10ºC - Relative humidity 85% or less 50ºC /(when operating with an external power supply, no condensation)
    0ºC - 40ºC /Relative humidity 85% or less (when operating with battery, no condensation)
    Storage temperature and humidity range -20ºC - 60ºC / Relative humidity 75% or less (no condensation)
    Power source
    Rechargeable Lead storage battery (12V)* Charging time: approx. 8 hours / AC Power supply (100V - 240V, 50/60Hz)
    * Continuous measuring time: Approx. 4 hours (a load of 100MΩ at the Insulation resistance 12000V Range.)
    Approx. 2 hours (Max current consumption in range while rated currents are maintained.)
    Dimension
    330 (L) × 410 (W) × 180 (D) mm *Instrument and Hard case
    Weight
    Approx. 9kg (including battery) *Instrument and Hard case
    Accessories
    7170 (Power cord[EU]) or 7240 (Power cord[UK])
    7224A (Earth cord)
    7225A (Guard cord)
    7226A (Line probe)
    7227A (Line probe with alligator clip)
    8029 (Extension prod)
    8212-USB (USB adapter)
    Instruction manual
    Optional accessories
    7254 (Longer Line probe with alligator clip)
    Ada masalah dengan produk ini?

    ULASAN PEMBELI

    Toped Illustration

    Belum ada ulasan untuk produk ini

    Beli produk ini dan jadilah yang pertama memberikan ulasan