Download Tokopedia App
Tentang TokopediaMulai Berjualan PromoTokopedia Care
tokopedia-logo
Kategori
Atur jumlah dan catatan

Stok Total: 500

Subtotal

Rp204.030

W3002 Digital Control Temperature Microcomputer Thermostat Switch New Thermoregulator 12/24/220V

Rp204.030
  • Kondisi: Baru
  • Waktu Preorder: 30 Hari
  • Min. Pemesanan: 1 Buah
  • Etalase: Semua Etalase
Brand Name : GlintDeer
Model Number : XH-W3002 /W3002 temperature controller
Type : K
Usage : Household
Origin : Mainland China
Theory : Temperature Controller
Certification : CE
Style : Standing and Wall Hanging
Display Size : 1.9 Inches & Under
Power Type : None
Display Type : DIGITAL
Cable Length : 1M
Max Measuring Temperature : 100C - 119C
Screw : M12*1.5
Measure Type : K
Is Smart Device : no


Specification:
Supply voltage: 12V/24V/220V.
Temperature range: -50-120 degrees.
Range of temperature control: -50-120 degrees.
Temperature control accuracy: + 0.1 degrees.
Temperature measurement accuracy: + 0.2 degrees.
Load power: 120/240/1500W.
Measuring input: NTC10K waterproof probe L=1 M.
Output type: direct output.
Output capacity: maximum 10A.
Mounting hole distance: 73mm (hole distance 4mm).
Size: 60 * 45 * 31mm.
Color: white & gray.

P0 Set startup temperature:

Press the setting button once to enter the internal menu, which defaults to P0. Press the setting button again, and set the desired starting temperature through the up and down buttons.

P1 Set stop temperature:

Press the setting button once to enter the internal menu. The digital display is P0, and switch to P1 through the up and down buttons. Press the setting button again to set the desired stop temperature through the up and down buttons.

P2 Set temperature correction:

Enter the internal menu, switch to P2 using the up and down buttons, press the setting button again, and set the required calibration temperature using the up and down buttons. In the setting, if the detected temperature value is 0.5 C greater than the actual temperature value, the calibration temperature that needs to be set is -0.5 C. If the detected temperature value is 1 lower than the actual temperature value, the calibration temperature that needs to be set is 1 .

Detected temperature corrected temperature=actual temperature.

P3 Set Delay Start:

Enter the internal menu, switch to P3 using the up and down buttons, press the set button again, and set the desired delay time (in minutes) using the up and down buttons.

Delayed start is generally used for compressor refrigeration. If it is used for refrigerators and freezers, this value needs to be set to 3-6 minutes based on the compressor return pressure. (If you are not using the compressor control or do not need the delay function, skip this option directly)

Heating mode:

Start temperaturestop temperature (the program automatically determines that the working mode is refrigeration mode)

Setting method:

Press the setting button to enter the internal menu, set the start temperature through the P0 value, and stop temperature through the P1 value

Use Case:

Control cabinet heat sink, stop cooling at 26 , and restart the heat sink when the temperature rises to 30 . How to set it?

1. Confirm that the working mode is refrigeration mode, and start temperature>stop temperature.

Use Case:

Control cabinet heat sink, stop cooling at 26 , and restart the heat sink when the temperature rises to 30 . How to set it?

1. Confirm that the working mode is refrigeration mode, and start temperature>stop temperature.

2. Press the setting button to enter the internal menu, select P0 to start the temperature, and set the P0 value to 30 .

3. Press the setting button to enter the internal menu, select P1 to stop the temperature setting, and set the P1 value to 26 .

Example of using scenario settings:

How do I set the temperature for hatching chicks to be between 37.5 and 38 ?

1. Short press the setting key to display P0 on the screen, then short press the setting key to display the current starting temperature. Press the up/down keys to adjust the starting temperature to 37.5 (no operation for 5 seconds, automatically save and exit)

2. Short press the setting button to display P0 on the screen, press the up button to switch to P1, and then short press the setting button to display the current stop temperature. Press the up/down button to adjust the stop temperature to 38

3. After setting, the temperature controller will control the heating equipment at 37.5 for heating. When the temperature rises to 38 , it will stop, and when the temperature drops to 37.5 , it will start heating again and continue cycling

The actual measured temperature is 35 , and the temperature controller displays 35.6 . How to calibrate?

1. Short press the setting button to display P0 on the screen, press the up button to switch to P2, and then press the setting button to display the current temperature calibration value. Press the up/down button to adjust the calibration to -0.6 (the temperature displayed by the temperature controller is 0.6 higher than the actual measured temperature)

Ada masalah dengan produk ini?