IDM-7842MG Ethernet Switch plus Isolated Modbus Gateway

Rp2.300.000
  • Kondisi: Baru
  • Min. Pemesanan: 1 Buah
  • Etalase: Modbus Gateway
IDM-7842MG Ethernet Switch plus Isolated Modbus Gateway

IDM-7842MG is a modbus gateway product dedicated to connecting Modbus TCP devices and Modbus RTU/ASCII devices.

IDM-7842MG is an isolated Modbus gateway device with multiple network ports. It integrates 5 port 10/100M switches and 2 serial port Modbus gateways. Users can use any port and 2 port RS-485/232 serial port to convert Modbus TCP and Modbus RTU/ASCII protocol. The 2 port RS-485/232 serial port has photoelectric isolation. It is integrated with Modbus TCP, Modbus RTU and Modbus ASCII protocol, and the serial port can be configured flexibly into RS-485 or RS-232 mode through software, which can easily realize the connection between Modbus Ethernet device and Modbus serial device.

Product Details :
1, 32 bit ARM Cortex-m3 CPU
2, 5-Ports 10/100M Ethernet interface, with switch function
3, Support 2-Port RS-485/232 serial port, two serial port can set different baud rate
4. RS-485/232 serial port photoelectric isolation, 1500V isolation voltage, 600W surge
protection, 15KV electrostatic protection
5. Redundant DC9~30V or AC18~30V dual power input
6. Integrated IEEE 802.3 10Base-T,IEEE 802.3u 100Base-T(X),ARP, IP, ICMP, IGMP,
UDP, TCP, DHCP, DNS,MODBUS TCP, MODBUS RTU, MODBUS ASCII protocol
7. Provide 4 mode of work:
RTU_ Master--TCP_ Slaver, TCP_ Master--RTU_ Slaver
ASCII_ Master--TCP_ Slaver, TCP_ Master--ASCII_ Slaver
8. Maximum support for 32 Modbus TCP master stations and 4 Modbus TCP slave stations
9. Support two Modbus RTU/ASCII master stations and Modbus slave communication 10. The automatic adaptive function of the time interval of the character
11, Provide ID mapping function to realize the management of host ID number
12. The local port, the target IP address, and the target port number can be set
13, Can be configured through Web Server, Telnet, MG Configuration tools
14, MG Configuration tools support
Windows98/me/NT/2000/XP/WIN7/WIN8/WIN10 operating system

Power Adaptor NOT included.