Atur jumlah dan catatan
Stok Total: Sisa 1
Subtotal
Rp20.000.000
HONEYWELL RP-2002 NOTIFIER
Rp20.000.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: SMOKE DETECTOR
HONEYWELL RP-2002 NOTIFIER
Welcome to Aaron Impex
DESCRIPTION
Make: Honeywell
Spare Name: Fire Alarm Panel Display
Type: RP-2002E
Condition: Used
Our Ref: AI-10010690
The RP-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The RP-2002 provides reliable fire detection, signaling, and protection for commercial, industrial and institutional buildings requiring agent-based releasing.
Features
• Listed to UL Standard 864, 9th edition.
• FM Approved.
• Designed for agent releasing standards NFPA 12, 12A, 12B, and 2001.
• Meets International Building Code (IBC) seismic requirements.
• Disable/Enable control per input zone and output zone.
• Extensive transient protection.
• Dual hazard operation.
• Adjustable pre-discharge, discharge, and water flow delay timers.
• Cross-zone (double-interlock) capability.
• Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
• Four programmable Style Y (Class B) output circuits - (special application power).
• Strobe synchronization:
– System Sensor
– Wheelock
– Gentex
– Faraday
– Amseco
• Three programmable Form-C relays.
• 7.0 amps total of 24 VDC output current.
• Resettable and non-resettable output power.
• Built-in Programmer.
• ANN-BUS connector for communication with optional devices (up to 8 total of any of the following):
– N-ANN-80 Remote LCD Annunciator
– N-ANN-I/O LED Driver
– N-ANN-S/PG Printer Modules
– N-ANN-RLY Relay Module
– N-ANN-LED Annunciator Module
• 80-character LCD display (backlit).
• Real-time clock/calendar with daylight savings time control.
• History log with 256 event storage.
• Piezo sounder for alarm, trouble, and supervisory.
• 24-volt operation.
• Low AC voltage sense.
• Outputs Programmable for:
– Releasing Circuits or NACS
• NACs programmable for:
– Silence Inhibit
– Auto-Silence
– Strobe Synchronization
– Selective Silence (horn-strobe mute)
– Temporal or Steady Signal
– Silenceable or Non-silenceable
– Release Stage Sounder
• Automatic battery charger with charger supervision.
• Optional Dress Panel DP-51050 (red).
• Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet.
• Optional N-CAC-5X Class A Converter Module for Outputs and IDCs.
• Optional 4XTM Municipal Box Transmitter Module.
• Optional Digital Alarm Communicators (411, 411UD, 411UDAC).
• Optional ANN-SEC card for a secondary ANN-BUS.
System Capacity:
• Annunciators 8
Electrical Specifications:
• RP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps
• RP-2002E (FLPS-7 Power Supply): 240 VAC, 50/60 Hz, 2.085 amps
• Wire size: minimum 14 AWG (2.0 mm²) with 600 V insulation, supervised, non-power-limited
Temperature and Humidity Range:
This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F.
Welcome to Aaron Impex
DESCRIPTION
Make: Honeywell
Spare Name: Fire Alarm Panel Display
Type: RP-2002E
Condition: Used
Our Ref: AI-10010690
The RP-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The RP-2002 provides reliable fire detection, signaling, and protection for commercial, industrial and institutional buildings requiring agent-based releasing.
Features
• Listed to UL Standard 864, 9th edition.
• FM Approved.
• Designed for agent releasing standards NFPA 12, 12A, 12B, and 2001.
• Meets International Building Code (IBC) seismic requirements.
• Disable/Enable control per input zone and output zone.
• Extensive transient protection.
• Dual hazard operation.
• Adjustable pre-discharge, discharge, and water flow delay timers.
• Cross-zone (double-interlock) capability.
• Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
• Four programmable Style Y (Class B) output circuits - (special application power).
• Strobe synchronization:
– System Sensor
– Wheelock
– Gentex
– Faraday
– Amseco
• Three programmable Form-C relays.
• 7.0 amps total of 24 VDC output current.
• Resettable and non-resettable output power.
• Built-in Programmer.
• ANN-BUS connector for communication with optional devices (up to 8 total of any of the following):
– N-ANN-80 Remote LCD Annunciator
– N-ANN-I/O LED Driver
– N-ANN-S/PG Printer Modules
– N-ANN-RLY Relay Module
– N-ANN-LED Annunciator Module
• 80-character LCD display (backlit).
• Real-time clock/calendar with daylight savings time control.
• History log with 256 event storage.
• Piezo sounder for alarm, trouble, and supervisory.
• 24-volt operation.
• Low AC voltage sense.
• Outputs Programmable for:
– Releasing Circuits or NACS
• NACs programmable for:
– Silence Inhibit
– Auto-Silence
– Strobe Synchronization
– Selective Silence (horn-strobe mute)
– Temporal or Steady Signal
– Silenceable or Non-silenceable
– Release Stage Sounder
• Automatic battery charger with charger supervision.
• Optional Dress Panel DP-51050 (red).
• Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet.
• Optional N-CAC-5X Class A Converter Module for Outputs and IDCs.
• Optional 4XTM Municipal Box Transmitter Module.
• Optional Digital Alarm Communicators (411, 411UD, 411UDAC).
• Optional ANN-SEC card for a secondary ANN-BUS.
System Capacity:
• Annunciators 8
Electrical Specifications:
• RP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps
• RP-2002E (FLPS-7 Power Supply): 240 VAC, 50/60 Hz, 2.085 amps
• Wire size: minimum 14 AWG (2.0 mm²) with 600 V insulation, supervised, non-power-limited
Temperature and Humidity Range:
This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F.