Atur jumlah dan catatan
Stok Total: Sisa 1
Subtotal
Rp2.690.000
EMERSON MAS 2600 Transducer Transmitter Hyrobox Ecosounder
Rp2.690.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: Enterprise
EMERSON MAS 2600 with approximately 27 m cable lengh (see picture)
Additional Bonus: Hydrobox Dual Channel Syswest (see picture)
G10-30-04/1P, Art No/ 64892
MAS 2600 PDCR 9411-1102-4, 350 mBar/ g
The MAS 2600 is a 2-wire 4-20 mA level transmitter consisting of a transducer, an amplifier and an interconnecting cable
Transducer Ranges:
Gauge= 0 - 3.5 / 0 - 7 / 0 - 16 / 0 - 35 m H2O
Absolute= 0 - 20.394 / 0 - 35.690 m H2O
Accuracy: 0.25% F.S. at 20C
Stability: Max. 0.1% / Year
TEB (Total Error Band): 0.4% F.S. at 0 to +50C; 2.0% F.S. at -20 to +80C
Overload Capability: Minimum 4 x transducer range with no changes in calibration.
6 x transducer range burst pressure.
Built-in Temperature Sensor Pt100 Optional (for safe area only)
Output Current: 4-20 mA DC, loop powered 2-wire system
Current Limiting: Typical= 25 mA; Maximum= 32 mA
Sensor Materials:
Housing Titanium Grade 2
Diaphragm Titanium Grade 4
Transducer cable:
Safe area Maximum 300 m
Intrinsically safe in hazardous area= Standard cable: 44m, High temperature cable: 34 m
Conditions
New—open box: The item is in excellent, new condition with no functional defects.
Additional Bonus: Hydrobox Dual Channel Syswest (see picture)
G10-30-04/1P, Art No/ 64892
MAS 2600 PDCR 9411-1102-4, 350 mBar/ g
The MAS 2600 is a 2-wire 4-20 mA level transmitter consisting of a transducer, an amplifier and an interconnecting cable
Transducer Ranges:
Gauge= 0 - 3.5 / 0 - 7 / 0 - 16 / 0 - 35 m H2O
Absolute= 0 - 20.394 / 0 - 35.690 m H2O
Accuracy: 0.25% F.S. at 20C
Stability: Max. 0.1% / Year
TEB (Total Error Band): 0.4% F.S. at 0 to +50C; 2.0% F.S. at -20 to +80C
Overload Capability: Minimum 4 x transducer range with no changes in calibration.
6 x transducer range burst pressure.
Built-in Temperature Sensor Pt100 Optional (for safe area only)
Output Current: 4-20 mA DC, loop powered 2-wire system
Current Limiting: Typical= 25 mA; Maximum= 32 mA
Sensor Materials:
Housing Titanium Grade 2
Diaphragm Titanium Grade 4
Transducer cable:
Safe area Maximum 300 m
Intrinsically safe in hazardous area= Standard cable: 44m, High temperature cable: 34 m
Conditions
New—open box: The item is in excellent, new condition with no functional defects.
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan