Atur jumlah dan catatan
Stok Total: Sisa 3
Subtotal
Rp5.880.000
Jual LUTRON O2H-9903SD O2 Meter + Humidity Temperature
Rp5.880.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: LUTRON
* Air quality measurement application, multi-function : , O2 ( Oxygen in air ), Humidity, temperature measurement.
* Real time recorder, save the data into the SD memory card and can be down load to the Excel, extra software is no need. User can make the further data or graphic
analysis by themselves. under the Excel software.
* At the same time, the SD memory card can record 2 probe's data ( %RH/Temp. and O2 ) along with the time information into the one Excel file at the same time.
Range 0 to 30 %O2. Resolution 0.1 %O2.
* Air oxygen Accuracy ± ( 1 % reading + 0.2 % O2 ). @ After calibration
Response time ≦ 15 second @ t 90
Overload protection 100 %O2.
Environment pressure range 0.9 to 1.1 atmosphere.
Expected life time ≧2 years.
Alarm If the measurement Air oxygen
value < 18.0 %O2, the buzzer will sound for warning.
Temperature Range 0 ℃ to 50 ℃
Resolution 0.1 degree
Accuracy ℃ : ± 0.8 ℃
HUMIDITY
Range 5 % to 95 % R.H.
Resolution 0.1 % R.H.
Accuracy ≧70% RH :
± (3% reading + 1% RH). < 70% RH : ± 3% RH.
Range 0 ℃ to 50 ℃
Temperature Resolution 0.1 degree
Accuracy ℃ ± 0.8 ℃.
Dew Point Temp. ( Humidity )
℃ Range -25.3 ℃ to 48.9 ℃ Resolution 0.1 ℃
℉ Range -13.5 ℉ to 120.1 ℉.
Resolution 0.1 ℉.
Wet bulb Temp. ( Humidity )
℃ Range -21.6 ℃ to 50.0 ℃ Resolution 0.1 ℃
℉ Range -6.9 ℉ to 122.0 ℉. Resolution 0.1 ℉.
Remark :
* Wet bulb display value is calculated from the Humidity/Temp. measurement automatically.
* The Welt bulb accuracy is sum accuracy value of Humidity & Temperature measurement..
Accessories Included ( Termasuk )
Instruction manual
Hard carrying case, CA-08
Humidity probe 1 PC
O2 probe 1 PC
Optional Accessories ( Tidak termasuk )
* Battery AA=6 Pcs
* SD memory card
* AC to DC 9V adapter.
* Real time recorder, save the data into the SD memory card and can be down load to the Excel, extra software is no need. User can make the further data or graphic
analysis by themselves. under the Excel software.
* At the same time, the SD memory card can record 2 probe's data ( %RH/Temp. and O2 ) along with the time information into the one Excel file at the same time.
Range 0 to 30 %O2. Resolution 0.1 %O2.
* Air oxygen Accuracy ± ( 1 % reading + 0.2 % O2 ). @ After calibration
Response time ≦ 15 second @ t 90
Overload protection 100 %O2.
Environment pressure range 0.9 to 1.1 atmosphere.
Expected life time ≧2 years.
Alarm If the measurement Air oxygen
value < 18.0 %O2, the buzzer will sound for warning.
Temperature Range 0 ℃ to 50 ℃
Resolution 0.1 degree
Accuracy ℃ : ± 0.8 ℃
HUMIDITY
Range 5 % to 95 % R.H.
Resolution 0.1 % R.H.
Accuracy ≧70% RH :
± (3% reading + 1% RH). < 70% RH : ± 3% RH.
Range 0 ℃ to 50 ℃
Temperature Resolution 0.1 degree
Accuracy ℃ ± 0.8 ℃.
Dew Point Temp. ( Humidity )
℃ Range -25.3 ℃ to 48.9 ℃ Resolution 0.1 ℃
℉ Range -13.5 ℉ to 120.1 ℉.
Resolution 0.1 ℉.
Wet bulb Temp. ( Humidity )
℃ Range -21.6 ℃ to 50.0 ℃ Resolution 0.1 ℃
℉ Range -6.9 ℉ to 122.0 ℉. Resolution 0.1 ℉.
Remark :
* Wet bulb display value is calculated from the Humidity/Temp. measurement automatically.
* The Welt bulb accuracy is sum accuracy value of Humidity & Temperature measurement..
Accessories Included ( Termasuk )
Instruction manual
Hard carrying case, CA-08
Humidity probe 1 PC
O2 probe 1 PC
Optional Accessories ( Tidak termasuk )
* Battery AA=6 Pcs
* SD memory card
* AC to DC 9V adapter.
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan