MAX30100 MAX30102  Heart Rate Oximetry Sensor Module Heart Rate Sensor Breakout Ultra-Low Power Consumption For Arduino

Rp108.000
  • Kondisi: Baru
  • Min. Pemesanan: 1 Buah
  • Etalase: Semua Etalase
Product Features
The MAX30102 is an integrated pulse oximeter and heart rate monitor biosensor module. It integrates a red LED and an infrared LED, photodetector, optical device, and low-noise electronic circuitry with ambient light suppression. The MAX30102 uses an 18V power supply and a separate 50V power supply for internal LEDs. Wear the device for heart rate and blood oxygen collection, and wear it on your fingers, earlobes and wrists. The standard I2C-compatible communication interface can transmit the collected values to the Arduino, KL25Z and other microcontrollers for heart rate and blood oxygen calculation. In addition, the chip can also shut down the module through software, the standby current is close to zero, and the power supply is always maintained. Because of its excellent performance, the chip is widely used in the Samsung Galaxy S series mobile phones. The chip integrates a glass cover to effectively eliminate external and internal light interference and has the best reliable performance.
Product Parameters
LED peak wavelength: 660nm/880nm
LED supply voltage: 3.3~5V
Detection signal type: Light reflection signal (PPG)
Output signal interface: I2C interface
Communication interface voltage: 18~3.3V~5V (optional)
Board reserved assembly hole size: 0.5X8.5mm
Working Principle
Light-dissolving method: measuring the pulse and blood oxygen saturation by using human tissue to cause different light transmittance when the blood vessel beats;
Light source: a specific wavelength illuminating pole tube selective for oxyhemoglobin (HbO2) and hemoglobin (Hb) in arterial blood;
Transmittance is converted into electrical signal: the volume of the arterial pulsation is changed to the light transmittance of the light. At this time, the light is reflected by the human body tissue by photoelectric conversion, converted into an electrical signal and amplified and output.
Pin Description
VIN: main power supply input terminal 1.8V-5V;
3-bit pad: Select the pull-up level