Atur jumlah dan catatan
Stok Total: 100000
Subtotal
Rp414.000
FrSky FLD-02 Telemetry Display Screen
Rp414.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: Transmitter-Receiver Accesories, Simulator
Specifications:
Model: FLD-02
Compatibility: FrSky DFT, DJT and DHT
Dimension: 55*40*12mm
Pixel: 128*64
Features:
1) Show all connected sensors data;
2) Capable of programming alarm thresholds and directions;
3) Firmware upgradable.
Installation:
Connect FrSky FLD-02 to the UART and power connection on FrSky telemetry module (Rxd, Txd, +5V, GND) by the provided cable. Confirm the orientation is correct and make sure both switches on the telemetry module are OFF.
Screen structures:
Main Screen:
FrSky Logo
Version Number
Data Screen
Menu Screen
FrSky Website
Menu Screen:
Blade: Blade Number
Volt ratio: A1 & A2 Voltage Division Ratio
Unit Set: Speed (m/s or MPH)
Temperature (Celsius or Fahrenheit)
Altitude (M/Foot)
Alarm Set: A1_1/2, A2_1/2, RSSI_1/2
Note: Make sure the battery voltage division ratios are programmed in accordance with those of connected battery voltage sensors.
The alarm thresholds and directions (either above or below threshold) can be programmed. After alarm thresholds and directions are programmed, click OK. means these values have been remembered by the module.
Data Screen:
Screen-1:
GMT (H/M/S)
Fuel Level
A1 & A2 Voltage
Temperature 1 & 2
Rx RSSI & Tx RSSI
Screen-2:
Altitude
RPM
Speed
Rate
Ampere
Screen-3:
Total Voltage
Voltage for each cell
Note: Screen-3 shows up only when FrSky Lipo Voltage Sensor (FLVS-01) is connected, otherwise Screen-4 will show up after Screen-2.
Screen-4:
Acceleration X/Y/Z
Longitude & Latitude.
Model: FLD-02
Compatibility: FrSky DFT, DJT and DHT
Dimension: 55*40*12mm
Pixel: 128*64
Features:
1) Show all connected sensors data;
2) Capable of programming alarm thresholds and directions;
3) Firmware upgradable.
Installation:
Connect FrSky FLD-02 to the UART and power connection on FrSky telemetry module (Rxd, Txd, +5V, GND) by the provided cable. Confirm the orientation is correct and make sure both switches on the telemetry module are OFF.
Screen structures:
Main Screen:
FrSky Logo
Version Number
Data Screen
Menu Screen
FrSky Website
Menu Screen:
Blade: Blade Number
Volt ratio: A1 & A2 Voltage Division Ratio
Unit Set: Speed (m/s or MPH)
Temperature (Celsius or Fahrenheit)
Altitude (M/Foot)
Alarm Set: A1_1/2, A2_1/2, RSSI_1/2
Note: Make sure the battery voltage division ratios are programmed in accordance with those of connected battery voltage sensors.
The alarm thresholds and directions (either above or below threshold) can be programmed. After alarm thresholds and directions are programmed, click OK. means these values have been remembered by the module.
Data Screen:
Screen-1:
GMT (H/M/S)
Fuel Level
A1 & A2 Voltage
Temperature 1 & 2
Rx RSSI & Tx RSSI
Screen-2:
Altitude
RPM
Speed
Rate
Ampere
Screen-3:
Total Voltage
Voltage for each cell
Note: Screen-3 shows up only when FrSky Lipo Voltage Sensor (FLVS-01) is connected, otherwise Screen-4 will show up after Screen-2.
Screen-4:
Acceleration X/Y/Z
Longitude & Latitude.
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan