Atur jumlah dan catatan
Stok Total: 284
Subtotal
Rp437.000
4-wire Conventional Smoke Detector with Relay output 12v/24v smoke alarm Conventional Smoke Detector
Rp437.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: Semua Etalase
SELAMAT DATANG DI TOKO KAMI Model Number : YT142 Brand Name : zoanco Origin : Mainland China Certification : CE Type : Smoke Detector Place of Origin : Guangdong, China (Mainland) is_customized : Yes 4-wire Conventional Smoke Detector with Relay output 12v/24v smoke alarm Conventional Smoke Detector BEFORE INSTALLING NOTICE: This manual should be left with the owner/user of this equipment. IMPORTANT: The detector must be tested and maintained regularly following the proper authorities requirements. The detector should be cleaned at least once a year. 1. GENERAL DESCRIPTION The detectors are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most security alarm control panel. Two LEDs on each detector provide local 360 visible alarm indication. They flash every 5-6 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm,will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The detector can be restored to normal status automatically when the ambient smoke or temperature below the alarm value. 2. SPECIFICATIONS Operating Voltage Range: 9 to 28 VDC Volts Non-polarized Standby Current: 200A Maximum Alarm Current (LED on): 45mA Alarm Relay Contact Ratings: 1A@ 24V DC Operating Humidity Range: 95%RH(40C2C) Relative Humidity, Non-condensing Operating Temperature Range: -10C to 50C (14F to 122F) Smoke Alarm Sensitivity: 0.15~0.3dB/m Height: 55 mm installed in Base Diameter: 103 mm INSTALL THE DETECTOR BASE 1. Open area smoke or heat detectors are intended for mounting on a ceiling or a wall in accordance with the fire standard in your country. 2. Attach mounting base to ceiling or wall. The base of the detector can be mounted directly onto an electrical junction box such as an octagonal (75mm, 90mm or 100mm), a round (75mm), or a square (100mm) box without using any type of mechanical adapter. 3. Position all wires flat against terminals, and fasten the wires on the terminals, See Figure 1. 4. Terminals function description: Terminal 1: Relay Output -COM Terminal 2: Relay Output NO/NC (default NO) Terminal 3: DC Power Terminal 4: DC Power + INSTALL THE DETECTOR HEAD 1. Align detector head alignment mark line with the bases start alignment mark line as shown in Figure 2 2. Push the detector head into the base while turning it clockwise to secure it in place. 3. Do not install the detector head until the area is thoroughly cleaned of construction debris, dusts, etc. 4. After all detectors have been installed, apply power to the control panel. 5. Test the detector(s) as described in the TESTING section of this manual. 6. Notify the proper authorities that the system is in operation. ADJUSTING THE RELAY FOR NO/NC The default condition for the relay is normally open (NO). 1. To adjust the normal condition of the relay to normally closed (NC), use a flat head screwdriver to open the detector head form the bottom. 2. There is a jumper head next to the relay on the PCB. Remove the jumper head and reinsert it in the NC position. 3. Carefully reinstall the head front cover. Sebelum membeli suatu produk, Mohon dapat membaca deskripsi produk dengan cermat Harap tanyakan stok sebelum melakukan pemesanan ya kak Jika Anda memiliki pertanyaan, silakan hubungi kami.
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan