METRON QA-ST Electrical Safety Analyzer USA VERSION NEW
Rp9.900.000
METRON QA-ST ELECTRICAL SAFETY ANALYZER
USA VERSION
BRAND NEW
PRODUCT HIGHLIGHTS
OVERVIEW
· Manual and maximum simplicity
· Operating voltage from 90-140VAC US Model
· Power configuration test
· Supply Voltage measurements
· Ground wire resistance
· Ground, chassis, and patient leakage current
· Lead isolation test
· Lead to Lead leakage current
· Test loads: AAMI/ANSI ES1-1993 or IEC 60601.1
· RS-232 Standard Feature
· Automation with Ansur test integration software
The QA-ST is designed to quickly check electrical safety on medical and industrial devices. It is palm sized and very portable. The tests can be performed manually or in step-by-step mode. The results are displayed in a bright 4-digit LCD display.
The QA-ST performs all electrical safety test necessary to satisfy AAMI ESI, NFPA-99, VDE 751 and partly IEC 60601.1. It also features residual current measurements obtained by an internal current clamp. This presents a new leakage current measurement technique for convenient testing of medical equipment.
The QA-ST is available in two versions:
1-US Version, which includes AAMI/ANSI ES1-1993 lest load.
2- version, which includes IEC 6061.1 test load.
THIS IS THE USA VERSION
LINE VOLTAGE MEASUREMENT
POWER
CONSUMPTION
QA-ST
Ordering information
Range: 0-300 V*
Accuracy: +- 1% of reading.
+- 1 digit
Resolution: 1V
L-N
*Subject to the operation voltage range of the QA-ST model
CURRENT CAPACITY
15 Amps @ 100 Volts
(20 Amps limited duration).
15 Amps @ 120 Volts
(20 Amps limited duration).
10 Amps @ 230 Volts
(16 Amps limited duration).
RESISTANCE MEASUREMENT
DC-Source
Range: 0.00-18.0 Ohms
Range 1: 0.00-4.99 Ohms
Accuracy: +-2% of reading,
+-0.05 Ohms
Range 2: 5.0 – 18.0 Ohms
Accuracy: +-5% of reading,
+-0.5 Ohms
LEAKAGE CURRENT
Range: 0-1999 uA
Range 1: 0-99 uA
Accuracty: +-2 Ua, +-1 digit
Range 2: 100-1999 uA
Accuracy: +- 1% of reading, +-
1 digit
Resolution: 1 uA
US Version:
110 V (50/60) Hz = 200 mA
115 V (50/60) Hz = 200 mA
GENERAL INFORMATION
Temperature Requirements:
+15?59 to +35/95 C/F
while operation
0 to +50/122 C/F
for storage
Display:
Type: LCD
Numeric format 4 characters
Display control: Keypad
Power:
100 V/110V (US version)
Housing: Plastic case
Dimensions: D x W x H
191mm 135mm 45mm
Weight: 930 grams
Standard Accessories:
User/Service Manual
Test lead
Order Number:
US Version:
11040: QA-ST Electical Safety
Tester
Accessories:
Various power supply socket including: European Schuco, French Schuco, UK, Swiss, Australian, US.
11045: User/Service Manual QA-
ST
11150: Carrying Case
17260: Hard Case
17458: Test lead (Kelvin cable)
17024: Universal Banana Adapter
11050 ansur QA-ST Plug in
11051 ansur QA-ST Plug in
demo
11052: User Manual ansur QA-
ST Plug-In
15403: Data transfer cable, RS-
232
USA VERSION
BRAND NEW
PRODUCT HIGHLIGHTS
OVERVIEW
· Manual and maximum simplicity
· Operating voltage from 90-140VAC US Model
· Power configuration test
· Supply Voltage measurements
· Ground wire resistance
· Ground, chassis, and patient leakage current
· Lead isolation test
· Lead to Lead leakage current
· Test loads: AAMI/ANSI ES1-1993 or IEC 60601.1
· RS-232 Standard Feature
· Automation with Ansur test integration software
The QA-ST is designed to quickly check electrical safety on medical and industrial devices. It is palm sized and very portable. The tests can be performed manually or in step-by-step mode. The results are displayed in a bright 4-digit LCD display.
The QA-ST performs all electrical safety test necessary to satisfy AAMI ESI, NFPA-99, VDE 751 and partly IEC 60601.1. It also features residual current measurements obtained by an internal current clamp. This presents a new leakage current measurement technique for convenient testing of medical equipment.
The QA-ST is available in two versions:
1-US Version, which includes AAMI/ANSI ES1-1993 lest load.
2- version, which includes IEC 6061.1 test load.
THIS IS THE USA VERSION
LINE VOLTAGE MEASUREMENT
POWER
CONSUMPTION
QA-ST
Ordering information
Range: 0-300 V*
Accuracy: +- 1% of reading.
+- 1 digit
Resolution: 1V
L-N
*Subject to the operation voltage range of the QA-ST model
CURRENT CAPACITY
15 Amps @ 100 Volts
(20 Amps limited duration).
15 Amps @ 120 Volts
(20 Amps limited duration).
10 Amps @ 230 Volts
(16 Amps limited duration).
RESISTANCE MEASUREMENT
DC-Source
Range: 0.00-18.0 Ohms
Range 1: 0.00-4.99 Ohms
Accuracy: +-2% of reading,
+-0.05 Ohms
Range 2: 5.0 – 18.0 Ohms
Accuracy: +-5% of reading,
+-0.5 Ohms
LEAKAGE CURRENT
Range: 0-1999 uA
Range 1: 0-99 uA
Accuracty: +-2 Ua, +-1 digit
Range 2: 100-1999 uA
Accuracy: +- 1% of reading, +-
1 digit
Resolution: 1 uA
US Version:
110 V (50/60) Hz = 200 mA
115 V (50/60) Hz = 200 mA
GENERAL INFORMATION
Temperature Requirements:
+15?59 to +35/95 C/F
while operation
0 to +50/122 C/F
for storage
Display:
Type: LCD
Numeric format 4 characters
Display control: Keypad
Power:
100 V/110V (US version)
Housing: Plastic case
Dimensions: D x W x H
191mm 135mm 45mm
Weight: 930 grams
Standard Accessories:
User/Service Manual
Test lead
Order Number:
US Version:
11040: QA-ST Electical Safety
Tester
Accessories:
Various power supply socket including: European Schuco, French Schuco, UK, Swiss, Australian, US.
11045: User/Service Manual QA-
ST
11150: Carrying Case
17260: Hard Case
17458: Test lead (Kelvin cable)
17024: Universal Banana Adapter
11050 ansur QA-ST Plug in
11051 ansur QA-ST Plug in
demo
11052: User Manual ansur QA-
ST Plug-In
15403: Data transfer cable, RS-
232
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan