Atur jumlah dan catatan
Stok Total: 28
Subtotal
Rp69.000
KABEL INSTRUMENT CU/XLPE/OSCR/PVC/SWA/PVC-FR 2x2x1.5mm2 *FIRST CABLE*
Rp69.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: KABEL
READY STOCK
CU/XLPE/OSCR/PVC/SWA/PVC FR Cat.A
Stranded plain copper conductor
Cross-linked Polyethylene insulation ( XLPE )
Core twisted in pairs or triads
Colour coding for pair : black/white, continuously numbered
triad : black/white/red, continuously numbered
Overall Screen of plastic bonded aluminium mylar tape with tinned copper drain wire, approx. 25% overlapped
Bedding of polyvinylchloride ( PVC )
Galvanized steel wire armour
PVC outer sheath, flame retardant to IEC 60332-3C, black or blue colour
Available on request : Tinned conductors, PVC, XLPE or EPR insulations, sheathing of LSOH, oil & hydrocarbon resistant, anti termite, anti rodent, and other special sheath performance
Application
For the transmission of measuring data signals in power stations and industrial plants
This cable is suitable for fixed indoor,outdoor,or underground installations.
Electrical and Technical Data
Working Voltage : max. 500V
Test Voltage core/core : 2000V 50Hz 1 min
core /screen : 1000V 50Hz 1 min
Conductor Resistance L/R Ratio
0.5 mm2 0.75 mm2 1.00 mm2 1.50 mm2 2.50 mm2
max
7.6 Ω/km max
7.6 Ω/km max
7.6 Ω/km max
7.6 Ω/km max
7.6 Ω/km
25 μH/Ω 25 μH/Ω 25 μH/Ω 40 μH/Ω 60 μH/Ω
Insulation Resistance : min 5000 mΩ/km
Mutual Capacitance at 1 kHz single pair
max. 115 nF/km
2 to 4 pairs 90 nF/km 102 nF/km
above 4 pairs 75 nF/km 85 nF/km
Capacitance unbalance : max. 500 pf/500m
Inductance : max. 1 mH/km
Temperature Range, fixed : -300C to +900C
Minimum Bending Radius : 10 x cable diameter
Flame Retardancy : IEC-60332-1
Flame Propagation : IEC-60332-3-22 (Cat.A)
CU/XLPE/OSCR/PVC/SWA/PVC FR Cat.A
Stranded plain copper conductor
Cross-linked Polyethylene insulation ( XLPE )
Core twisted in pairs or triads
Colour coding for pair : black/white, continuously numbered
triad : black/white/red, continuously numbered
Overall Screen of plastic bonded aluminium mylar tape with tinned copper drain wire, approx. 25% overlapped
Bedding of polyvinylchloride ( PVC )
Galvanized steel wire armour
PVC outer sheath, flame retardant to IEC 60332-3C, black or blue colour
Available on request : Tinned conductors, PVC, XLPE or EPR insulations, sheathing of LSOH, oil & hydrocarbon resistant, anti termite, anti rodent, and other special sheath performance
Application
For the transmission of measuring data signals in power stations and industrial plants
This cable is suitable for fixed indoor,outdoor,or underground installations.
Electrical and Technical Data
Working Voltage : max. 500V
Test Voltage core/core : 2000V 50Hz 1 min
core /screen : 1000V 50Hz 1 min
Conductor Resistance L/R Ratio
0.5 mm2 0.75 mm2 1.00 mm2 1.50 mm2 2.50 mm2
max
7.6 Ω/km max
7.6 Ω/km max
7.6 Ω/km max
7.6 Ω/km max
7.6 Ω/km
25 μH/Ω 25 μH/Ω 25 μH/Ω 40 μH/Ω 60 μH/Ω
Insulation Resistance : min 5000 mΩ/km
Mutual Capacitance at 1 kHz single pair
max. 115 nF/km
2 to 4 pairs 90 nF/km 102 nF/km
above 4 pairs 75 nF/km 85 nF/km
Capacitance unbalance : max. 500 pf/500m
Inductance : max. 1 mH/km
Temperature Range, fixed : -300C to +900C
Minimum Bending Radius : 10 x cable diameter
Flame Retardancy : IEC-60332-1
Flame Propagation : IEC-60332-3-22 (Cat.A)
Ada masalah dengan produk ini?