is_customized : Yes
Theory : Current Sensor
Usage : MAGNETIC SENSOR
Model Number : new
Material : Polymer
Type : Magnetic Sensor
Output : Digital Sensor
Origin : Mainland China
Power Line Carrier Power Line Communication Module
Without any serial peripheral zero error
power supply module:6.5-20VDC
Module Output Power : 5VDC 100mA
Communication speed : 1200,2400,4800,9600 ( default 9600 ) even parity , no parity optional
Interface Type : TTL level serial interface RXD, TXD
Working environment : 220V 50/60Hz or low voltage DC
Communication distance : 1500m ( depending on the application specific communication from the environment)
Each frame length : unlimited
Power line carrier frequencies : 110kHz
Modulation and demodulation : FSK
Send modes: normal transmission mode / zero- transmit mode
Working temperature : -20 ~ +70 degree
Dimensions : 4.8 x2.8cm x 1.3cm (L x W x H)
VHH: the carrier module power 5.5-20V DC ; input
GND: To systematically ; Input / Output
VCC: 5V output , the microcontroller can be provided to users of small systems ; output
RXD: Carrier module receives UART data port , then the user MCU TXD; input
TXD: UART transmit data carrier module port , then the user microcontroller RXD; output
PLT-/PLT +: carrier -coupled input and output signals can be directly connected to 220V.
TES: Factory test port , users do not need to use vacant can ;
RST: Reset the port , low reset , you can take the user to force a reset control pin unconnected or use the power automatically reset.
B: Select the port baud rate
ā³ Pre-Order +/- Sampai Alamat 15-20 Harian
is_customized : Yes
Theory : Current Sensor
Usage : MAGNETIC SENSOR
Model Number : new
Material : Polymer
Type : Magnetic Sensor
Output : Digital Sensor
Origin : Mainland China
Power Line Carrier Power Line Communication Module
Without any serial peripheral zero error
power supply module:6.5-20VDC
Module Output Power : 5VDC 100mA
Communication speed : 1200,2400,4800,9600 ( default 9600 ) even parity , no parity optional
Interface Type : TTL level serial interface RXD, TXD
Working environment : 220V 50/60Hz or low voltage DC
Communication distance : 1500m ( depending on the application specific communication from the environment)
Each frame length : unlimited
Power line carrier frequencies : 110kHz
Modulation and demodulation : FSK
Send modes: normal transmission mode / zero- transmit mode
Working temperature : -20 ~ +70 degree
Dimensions : 4.8 x2.8cm x 1.3cm (L x W x H)
VHH: the carrier module power 5.5-20V DC ; input
GND: To systematically ; Input / Output
VCC: 5V output , the microcontroller can be provided to users of small systems ; output
RXD: Carrier module receives UART data port , then the user MCU TXD; input
TXD: UART transmit data carrier module port , then the user microcontroller RXD; output
PLT-/PLT +: carrier -coupled input and output signals can be directly connected to 220V.
TES: Factory test port , users do not need to use vacant can ;
RST: Reset the port , low reset , you can take the user to force a reset control pin unconnected or use the power automatically reset.
B: Select the port baud rate