Atur jumlah dan catatan
Stok Total: Sisa 2
Subtotal
Rp8.000.000
ARINST VNA-DL 1-8800 MHz two-port vector network analyzer
Rp8.000.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: Elektronik
Main properties:
Frequency range 1 - 8800 MHz
Measurement of parameters S11 and S21
Two measurement ports
Scan points 1000
Variable IF bandwidth 20 Hz - 1 kHz
The dynamic measurement range of the transmission coefficient is more than 80 dB
Ability to save presets and tracks (Touchstone)
Up to 4 charts on one screen
Compact size
Desktop form factor
Usage examples:
Make impedance matching using a Smith chart
Tune the antenna
Measure standing wave ratio
Measure the frequency response of passive and active devices
Measure the phase response of passive and active devices
Tune filters of the main selection, filters of the intermediate frequency
Measure attenuation in cable, microstrip line, waveguide
Measure the distance to the fault in the cable or its length
Attention! There is no factory calibration on all devices. When carrying out measurements using cable assemblies or additional adapters, as well as in their absence, it is necessary to calibrate the device according to the instructions. To calibrate the device, we recommend using ready-made calibration kits with N-type and SMA-type. To avoid premature wear of the instrument connectors, we recommend taking measurements with the screwed-on adapters supplied.
Advantages:
wide operating frequency range: from 1 to 8800 MHz
maximum scanning speed - 500 points / s
high precision in measuring the reflection coefficient: 0.25 dB and 0.7° in the entire frequency range
display of almost all possible interpretations of reflection coefficient and transmission coefficient
the ability to measure the distance to fault and loss in the cable
saving user presets and measurement results-traces (in Touchstone format)
power supply and control of the device via the USB port of the PC
low weight and dimensions: 250 grams , 155×127×29 mm
Frequency range 1 - 8800 MHz
Measurement of parameters S11 and S21
Two measurement ports
Scan points 1000
Variable IF bandwidth 20 Hz - 1 kHz
The dynamic measurement range of the transmission coefficient is more than 80 dB
Ability to save presets and tracks (Touchstone)
Up to 4 charts on one screen
Compact size
Desktop form factor
Usage examples:
Make impedance matching using a Smith chart
Tune the antenna
Measure standing wave ratio
Measure the frequency response of passive and active devices
Measure the phase response of passive and active devices
Tune filters of the main selection, filters of the intermediate frequency
Measure attenuation in cable, microstrip line, waveguide
Measure the distance to the fault in the cable or its length
Attention! There is no factory calibration on all devices. When carrying out measurements using cable assemblies or additional adapters, as well as in their absence, it is necessary to calibrate the device according to the instructions. To calibrate the device, we recommend using ready-made calibration kits with N-type and SMA-type. To avoid premature wear of the instrument connectors, we recommend taking measurements with the screwed-on adapters supplied.
Advantages:
wide operating frequency range: from 1 to 8800 MHz
maximum scanning speed - 500 points / s
high precision in measuring the reflection coefficient: 0.25 dB and 0.7° in the entire frequency range
display of almost all possible interpretations of reflection coefficient and transmission coefficient
the ability to measure the distance to fault and loss in the cable
saving user presets and measurement results-traces (in Touchstone format)
power supply and control of the device via the USB port of the PC
low weight and dimensions: 250 grams , 155×127×29 mm
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan