WMA Shop menjual RHM 04 Flow Sensor
Specifications:
- Type: RHM04-N1P1PM035A1JM-NN-NNNNNN-ANN
- Temperature Range: NT from -20 to +120°C / -4 to +248°F
- Pressure Range of Measuring Loops @ 120°C: Loops pmax = 157 bar in 35 Material and 221 bar in M3 Material
- Construction Type with pressure limits @ 120°C: Parallel block/manifold in SS316L with seals, pmax = 700 bar
- Material of Measuring Loops: Stainless Steel 316L / EN 1.4435 / UNS S31603
- Process Connection - prices refer to connections in standard material / SS 316: Flange ANSI ½" 150# RF/SF
- Electrical Connection to Transmitter: Terminal Box coated Aluminium - M20x1.5 cable entry, see Accessories for others
- Options for RHM 04: Without Option
- Hazardous Area Approvals: Without Ex Approval
- Design Compliance (pressure): Rheonik standard design based on EN codes (no PED - not for sales into EU)
- Performance Certification: No Performance Certification
- Flow Calibration Options: Standard - better 0.20% uncertainty / 3 points
- Density Calibration: No direct density. Volume indication is possible via fixed or calculated density by RHE 20/40
General Specifications:
- Nominal Flow (Qₙₒₘ)*: 12 kg/min (26.46 lb/min)
- Maximum Flow (Qₘₐₓ)*: 18 kg/min (39.68 lb/min)
- Typical Minimum Flow (Qₘᵢₙ)*: 0.06 kg/min (0.13 lb/min)
- Serial Tube / Single Path: Flow rates Qmax, Qnom and Qmin for "serial" sensors will be 50% of the above listed parallel/dual path version.
The RHM 04 is a fast response solution for batching, dispensing and filling applications. Very high pressure ratings allow deployment in processes where Coriolis meter use has not been possible in the past.
Harga termasuk PPN,
***Indent 4 bulan.
Specifications:
- Type: RHM04-N1P1PM035A1JM-NN-NNNNNN-ANN
- Temperature Range: NT from -20 to +120°C / -4 to +248°F
- Pressure Range of Measuring Loops @ 120°C: Loops pmax = 157 bar in 35 Material and 221 bar in M3 Material
- Construction Type with pressure limits @ 120°C: Parallel block/manifold in SS316L with seals, pmax = 700 bar
- Material of Measuring Loops: Stainless Steel 316L / EN 1.4435 / UNS S31603
- Process Connection - prices refer to connections in standard material / SS 316: Flange ANSI ½" 150# RF/SF
- Electrical Connection to Transmitter: Terminal Box coated Aluminium - M20x1.5 cable entry, see Accessories for others
- Options for RHM 04: Without Option
- Hazardous Area Approvals: Without Ex Approval
- Design Compliance (pressure): Rheonik standard design based on EN codes (no PED - not for sales into EU)
- Performance Certification: No Performance Certification
- Flow Calibration Options: Standard - better 0.20% uncertainty / 3 points
- Density Calibration: No direct density. Volume indication is possible via fixed or calculated density by RHE 20/40
General Specifications:
- Nominal Flow (Qₙₒₘ)*: 12 kg/min (26.46 lb/min)
- Maximum Flow (Qₘₐₓ)*: 18 kg/min (39.68 lb/min)
- Typical Minimum Flow (Qₘᵢₙ)*: 0.06 kg/min (0.13 lb/min)
- Serial Tube / Single Path: Flow rates Qmax, Qnom and Qmin for "serial" sensors will be 50% of the above listed parallel/dual path version.
The RHM 04 is a fast response solution for batching, dispensing and filling applications. Very high pressure ratings allow deployment in processes where Coriolis meter use has not been possible in the past.