The compact BC9191 room controller has an integrated PLC and the sensor/actuator interfaces necessary for room automation. This way, it can be used as an autonomous or local controller. Compared with the BC9191-0000, the BC9191-0100 has an RS485 interface so that, for example, room control units, weather stations, electric door openers or DMX slaves can be connected. Communication with the devices generally takes place via the Modbus RTU protocol, but may also take place via a serial protocol which the user can freely define. The K-bus interface makes extension by the entire range of Bus Terminals possible at any time.
PLC data Ethernet TCP/IP | BC9191-0100
Programming with TwinCAT 2 via Ethernet
Program memory 128 kbytes
Data memory 128 kbytes
Remanent data 2 kbytes
Runtime system 1 PLC task
Programming languages IEC 61131-3 (IL, LD, FBD, SFC, ST)
Online change yes
Technical data BC9191-0100
Number of Bus Terminals 64
Max. number of bytes fieldbus 512 byte input and 512 byte output
Ethernet interface 2 x RJ45 (switched)
Protocol TwinCAT ADS, Modbus TCP
Digital inputs 3 contacts (e.g. window contact, dew point, occupancy sensor)
Analog inputs 3 x 0…10 V (e.g. CO2 sensor, air quality sensor, brightness sensor)
1 x PT/Ni1000 (-20…+60 °C) for air temperature measurement
1 x resistance measurement for set value specification (0…10 KΩ)
Digital outputs 1 x 10 mA, LED output (max. 24 V)
1 x 230 V AC, 10 A, relay (e.g. air heater)
3 x 230 V AC, 1 A, relay (3-stage fan)
2 x 230 V AC, 1 A, triac (e.g. valves for heating and cooling)
Analog outputs 2 x 0…10 V (e.g. volumetric air flow controller)
Bus interface 2 x RJ45 (switched)
Sub bus system 1 x RS485
Supply voltage 230 V AC
Current supply K-bus 200 mA
PLC data Ethernet TCP/IP | BC9191-0100
Programming with TwinCAT 2 via Ethernet
Program memory 128 kbytes
Data memory 128 kbytes
Remanent data 2 kbytes
Runtime system 1 PLC task
Programming languages IEC 61131-3 (IL, LD, FBD, SFC, ST)
Online change yes
Technical data BC9191-0100
Number of Bus Terminals 64
Max. number of bytes fieldbus 512 byte input and 512 byte output
Ethernet interface 2 x RJ45 (switched)
Protocol TwinCAT ADS, Modbus TCP
Digital inputs 3 contacts (e.g. window contact, dew point, occupancy sensor)
Analog inputs 3 x 0…10 V (e.g. CO2 sensor, air quality sensor, brightness sensor)
1 x PT/Ni1000 (-20…+60 °C) for air temperature measurement
1 x resistance measurement for set value specification (0…10 KΩ)
Digital outputs 1 x 10 mA, LED output (max. 24 V)
1 x 230 V AC, 10 A, relay (e.g. air heater)
3 x 230 V AC, 1 A, relay (3-stage fan)
2 x 230 V AC, 1 A, triac (e.g. valves for heating and cooling)
Analog outputs 2 x 0…10 V (e.g. volumetric air flow controller)
Bus interface 2 x RJ45 (switched)
Sub bus system 1 x RS485
Supply voltage 230 V AC
Current supply K-bus 200 mA