OCS-3RL (20.9-95.6%) Ultrasonic oxygen sensor with pressure/humidity detection for oxygen chamber and space aeration
Rp1.055.000
Theory : Optical Sensor
Usage : Gas Sensor
Model Number : OCS-3RL
Material : Polymer
Type : Gas Sensor
Output : Analog Sensor
Origin : Mainland China
Main features:
High precision
Anti-interference ability
Quick response
Good long-term stability
No need to adjust regularly
Long life
With atmospheric pressure and ambient humidity compensation
Precautions for use
Ensure that the detected gas is water-free, oil-free and dust-free.
Without the permission of the manufacturer, the sensor shall not be disassembled, and the sensor damage caused by the manufacturer will not be guaranteed or repaired.
This sensor and data manual may change due to technical improvement of the product without prior notice, please forgive me.
The company has the final interpretation of the sensor data manual.
Voltage data and air source data need to be provided before purchase.
Technical indicators:
Gas concentration detection range: 0 Other concentrations can be customized
Concentration resolution: 0.1%
Concentration detection accuracy: 1.5% F@ (5-55)
Sample gas requirements: water removal (no condensation); Dust filtration (? < 1 u m)
Detection cycle: 500ms
Preheating time: The machine can be measured, 10s to achieve basic accuracy
Digital Output: 9600bps?? UART???? 5V TTL / 3.3V CMOS
Inlet and outlet direction: no direction distinction
Operating temperature: below 10~50 (non-condensing)
Storage temperature: -20~65 below (non-condensing)
Relative humidity: 0 ~ 95%RH (non-condensing)
Maximum pressure: 150 kPa
Power supply: DC(5V-12V), 50mA
Dimensions: 45mm x 24mm x 24mm (L x W x H)
Sensor weight: 20g
Serial communication protocol
Baud rate: 9600bps
Character length: 1 start bit, 8 data bit, 1 stop bit, no check
Communication specification
All data in this agreement are hexadecimal data. "46" is decimal [70]
The protocol verification must contain 0x16 0x09 0x01 and CS bits. The data after the verification is correct and can be used normally.
By default, the sensor reports data twice every second. When the mainboard queries data, the sensor automatically switches to the answer mode and reports data to the mainboard instead of sending data twice a second.
Usage : Gas Sensor
Model Number : OCS-3RL
Material : Polymer
Type : Gas Sensor
Output : Analog Sensor
Origin : Mainland China
Main features:
High precision
Anti-interference ability
Quick response
Good long-term stability
No need to adjust regularly
Long life
With atmospheric pressure and ambient humidity compensation
Precautions for use
Ensure that the detected gas is water-free, oil-free and dust-free.
Without the permission of the manufacturer, the sensor shall not be disassembled, and the sensor damage caused by the manufacturer will not be guaranteed or repaired.
This sensor and data manual may change due to technical improvement of the product without prior notice, please forgive me.
The company has the final interpretation of the sensor data manual.
Voltage data and air source data need to be provided before purchase.
Technical indicators:
Gas concentration detection range: 0 Other concentrations can be customized
Concentration resolution: 0.1%
Concentration detection accuracy: 1.5% F@ (5-55)
Sample gas requirements: water removal (no condensation); Dust filtration (? < 1 u m)
Detection cycle: 500ms
Preheating time: The machine can be measured, 10s to achieve basic accuracy
Digital Output: 9600bps?? UART???? 5V TTL / 3.3V CMOS
Inlet and outlet direction: no direction distinction
Operating temperature: below 10~50 (non-condensing)
Storage temperature: -20~65 below (non-condensing)
Relative humidity: 0 ~ 95%RH (non-condensing)
Maximum pressure: 150 kPa
Power supply: DC(5V-12V), 50mA
Dimensions: 45mm x 24mm x 24mm (L x W x H)
Sensor weight: 20g
Serial communication protocol
Baud rate: 9600bps
Character length: 1 start bit, 8 data bit, 1 stop bit, no check
Communication specification
All data in this agreement are hexadecimal data. "46" is decimal [70]
The protocol verification must contain 0x16 0x09 0x01 and CS bits. The data after the verification is correct and can be used normally.
By default, the sensor reports data twice every second. When the mainboard queries data, the sensor automatically switches to the answer mode and reports data to the mainboard instead of sending data twice a second.