Tolong konfirmasi ketersediaan stock dan harga sebelum order
Size : M12 (Brass) / Double / Shielded Sensing distance : 4 mm ± 10% Connecting method : Pre-wired Body length : Short Output configuration : NPN Operation mode : NO Setting distance : 0 to 3.2 mm Differential travel : 10% max. of sensing distance Detectable object : Ferrous metal (The sensing distance decreases with non-ferrous metal.) Standard sensing object : 12 × 12 × 1 mm Response frequency : 1,000 Hz Power supply voltage : 10 to 30 VDC. (including 10% ripple (p-p)) Current consumption : 10 mA max Indicator : Operation indicator (Yellow LED) Protection circuit : Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Ambient air temperature : Operation and storage : -25 to 70ºC (with no icing or condensation) Ambient humidity : Operation and Storage: 35 to 95% Voltage influence : ±1% max. of sensing distance in 24 VDC ±15% Insulation resistance : 50 MΩ min. (at 500 VDC) between current-carrying parts and case Standard and listings : (1) IP67 (IEC60529) (2) EMC (EN60947-5-2)