Atur jumlah dan catatan
Stok Total: Sisa 1
Subtotal
Rp9.990.000
Water Hardness Tester Alat Ukur Kesadahan Air
Rp9.990.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: Peralatan Rumah
Spec :
Measuring Range:
0~10mmol/L; 0~401mg/L (Ca); 0~1000mg/L (CaCO3); 0~100fH (France Degree); 0~561mg/L (CaO); 0~56dH (German Degree); 0~20mmol/L (Boiler); 0~70eH (England Degree)
Temperature: 0 ~ 60.0
Resolution: Hardness: 0.01/0.1; Temp: 0.1
Accuracy: Hardness: 5% FS; Temp: 0.5
ATC: 5 ~ 50
Data Memory: 99 group
Buffer: B1: 2.0010-2 mmol/L
B2: 2.0010-1 mmol/L
B3: 2.00 mmol/L
Measuring range
0 ~ 10mmol/L0 ~ 401mg/L(Ca)
0 ~ 1000mg/L(CaCO3)
0 ~ 100fH(France Degree)
0 ~ 561mg/L(CaO)
0 ~ 56dH(German Degree)
0 ~ 20mmol/L(Boiler)
0 ~ 70eH (England Degree)
Resolution
0.01 and 0.1 water hardness units
Accuracy
5% FS
Temp. compensation
5 ~ 50automatic
Calibration Solution
B1 Calibration Solution 2.0010-2 mmol/L
B2 Calibration Solution 2.0010-1 mmol/L
B3 Calibration Solution 2.00 mmol/L
B3Calibration Solution also can be used for the soaking solution of electrode
Calibration Mode
(a)B1/B2 Calibrationusing B1 and B2 Calibration Solutionsuitable for < 2.0010-2 mmol/L low concentration water qualityfor example, boiler
water.
(b)Calibrationusing B2 and B3 Calibration Solutionsuitable forgeneral water quality.
Temperature
Measuring range 0 ~ 60
Resolution 0.1
Accuracy 0.5
Other Technical Parameter
Data storage 99 groups
Content Storage: serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way.
Power: 2x AA batteries
Dimension and weight
Unit(6512031)mm/180g
Carry Case (25521050)mm/790g
Quality & safe certificate :IISO9001:2000 and CE
Working Conditions
Ambient temperature (5~35)
Ambient humidity 85%RH
Measuring Range:
0~10mmol/L; 0~401mg/L (Ca); 0~1000mg/L (CaCO3); 0~100fH (France Degree); 0~561mg/L (CaO); 0~56dH (German Degree); 0~20mmol/L (Boiler); 0~70eH (England Degree)
Temperature: 0 ~ 60.0
Resolution: Hardness: 0.01/0.1; Temp: 0.1
Accuracy: Hardness: 5% FS; Temp: 0.5
ATC: 5 ~ 50
Data Memory: 99 group
Buffer: B1: 2.0010-2 mmol/L
B2: 2.0010-1 mmol/L
B3: 2.00 mmol/L
Measuring range
0 ~ 10mmol/L0 ~ 401mg/L(Ca)
0 ~ 1000mg/L(CaCO3)
0 ~ 100fH(France Degree)
0 ~ 561mg/L(CaO)
0 ~ 56dH(German Degree)
0 ~ 20mmol/L(Boiler)
0 ~ 70eH (England Degree)
Resolution
0.01 and 0.1 water hardness units
Accuracy
5% FS
Temp. compensation
5 ~ 50automatic
Calibration Solution
B1 Calibration Solution 2.0010-2 mmol/L
B2 Calibration Solution 2.0010-1 mmol/L
B3 Calibration Solution 2.00 mmol/L
B3Calibration Solution also can be used for the soaking solution of electrode
Calibration Mode
(a)B1/B2 Calibrationusing B1 and B2 Calibration Solutionsuitable for < 2.0010-2 mmol/L low concentration water qualityfor example, boiler
water.
(b)Calibrationusing B2 and B3 Calibration Solutionsuitable forgeneral water quality.
Temperature
Measuring range 0 ~ 60
Resolution 0.1
Accuracy 0.5
Other Technical Parameter
Data storage 99 groups
Content Storage: serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way.
Power: 2x AA batteries
Dimension and weight
Unit(6512031)mm/180g
Carry Case (25521050)mm/790g
Quality & safe certificate :IISO9001:2000 and CE
Working Conditions
Ambient temperature (5~35)
Ambient humidity 85%RH
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan