Pemutus Sirkuit Arus Sisa dengan Proteksi Beban Lebih (RCBO) / ELCB (Pemutus Sirkuit Kebocoran Bumi) - tipe A - ABB / Stotz (seri DS200) - DS201 C16 A30 - 2 kutub (1P+N) - Arus terukur 16A - Kurva C - Sensitivitas arus sisa 30mA - Kapasitas pemutusan hubung singkat (Icn) 6kA / 6000A - Pemasangan rel DIN (lebar 35mm) - 2 modul (2M)
Fungsi Pemutus Sirkuit Arus Sisa dengan Proteksi Beban Lebih (RCBO) / ELCB (Earth Leakage Circuit Breaker) Desain Tipe A Polandia 2 kutub (1P+N) Nilai arus terukur 16A Sensitivitas arus sisa 30mA Tegangan Terukur (AC) - Fase ke Netral Tegangan 240V Tegangan isolasi terukur (Ui) 500 voltase Kurva tersandung C Kapasitas pemutusan arus hubung singkat maksimum (Icu) 10kA Kapasitas pemutusan arus hubung singkat (Icn) 6kA Kapasitas pemutus arus hubung singkat layanan (Ics) 6kA (230Vac) Ukuran dalam modul (1 modul = 18mm) 2 Modul Mode pemasangan rel DIN Tinggi Bersih (mm) 85 mm Lebar Bersih (mm) 35 mm Kedalaman Bersih (mm) 69 mm Daya tahan listrik (dengan beban) 10.000 operasi Daya tahan mekanis (tanpa beban) 20.000 operasi
spesifiaksi - Fungsi proteksi sirkit fasa tunggal terhadap arus gangguan ke tanah berbentuk (AC sinusoidal) arus beban lebih dan arus hubung pendek yang terintegrasi menjadi satu. Dan proteksi terhadap sentuhan tak langsung dan juga sentuhan langsung (dengan IΔn = 30, 100 dan 300mA) Aplikasi perumahan, gedung komersial dan industri Icu 6 kA Kurva C Im (pemutusan magnetis) antara 5 In dan 10 In - Technical Standards:IEC/EN 61009-1, IEC/EN 61009-2-1 Tripping Characteristic:C Type of Residual Current:AC type Rated Voltage (Ur):230 V Rated Operational Voltage:230 / 240 V AC Rated Insulation Voltage (Ui):500 V Test Voltage (Ut):170 ... 264 V Dielectric Test Voltage:2 kV Primary Rated Impulse Withstand Voltage:4 kV Input Voltage Type:AC Rated Current (In):20 A Rated Residual Current:30 mA Rated Short-Circuit Capacity:6 kA Rated Ultimate Short-Circuit Breaking Capacity (Icu):10 kA Rated Residual Breaking Capacity (IΔm):EN 61009-1 6000 A IEC 61009-1 6000 A Rated Conditional Short-Circuit Current (Inc):10 kA Rated Service Short-Circuit Breaking Capacity (Ics):7.5 kA Maximum Surge Current:0 kA Leakage Current Type:AC Frequency (f):50/60 Hz Rated Frequency (f):50 … 60 Hz Power Loss:Average per Pole 2,8 W Phase Pole 3,8 W Neutral Pole 1,8 W Total 5,7 W Power Supply Connection:Arbitrary Contact Position Indication:Red ON / Green OFF Energy Limiting Class:3 Electrical Endurance:10000 cycle Mechanical Endurance:20000 cycle Number of Poles:2 Number of Protected Poles:1 Number of Modular Spacings per DIN Rail:2 Fault Indication:Blue flag on toggle Operating Characteristic:Instantaneous Overvoltage Category:III Position of Neutral Terminals:Right Tightening Torque:2.8 N·m
Ada masalah dengan produk ini?
ULASAN PEMBELI
5.0/ 5.0
100% pembeli merasa puas
1 rating • 0 ulasan
5
(1)100%
4
(0)0%
3
(0)0%
2
(0)0%
1
(0)0%
Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan