Kyoritsu KEW 5410 RCD (ELCB) Tester

Rp19.500.000
    • Measurement of RCD trip time
     Conducting testing of rated residual non-operating currents at × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges
    • Measurement of trip out current
     Measuring trip out current by varying current automatically
    • Remote Test
     Enabling a user to hold the Test Leads with his both hands by locking the Test Button
     Measurement will automatically start when the main voltage is detected
    • Voltage Measurement
     Carrying out a constant measurement of voltage in the stand-by mode at each Range
    • Auto-detection of Contact voltage
     Detecting the voltage to earth of Earth electrodes or Protective conductors during RCD test
     - when applying test currents - at measurement using EARTH in order to prevent electrical shocks caused by the damaged earth
     Measurement will be ceased at AC50V or more
    • Dust and Water proof
     Dust and Water proof construction (designed to IEC 60529 IP54)
    • Backlight
     Facilitating working at dimly illuminated locations

    Measurement of RCD trip time - Measurement of trip out current :
    Range × 5 × 1 × 1/2 AUTO RAMP(mA)
    Rated Voltage 100V±10%
    200V-10%~+32%
    400V±10%
    50/60Hz
    Test current 15/30/50/100mA 15/30/50/100/200/500mA
    Measuring range Testing time
    0ms~200ms Testing time
    0ms~2000ms 40 - 110% of lΔn
    (goes up by 5%)
    Testing time
    300ms × 15steps
    Accuracy
    (Trip Time) 1%rdg±3dgt Test Current at each step
    -4%~+4%

    Accuracy
    (Trip Time)
    +2%~+8%dgt -8~-2%dgt
    Voltage Measurement
    Measuring range 80V~450V 50/60Hz
    Accuracy 2%rdg±4dgt
    Applicable standards IEC 61010-1 CAT III 300V / CAT II 400V Pollution degree2
    IEC 61010-031
    IEC 61557-1, 6
    IEC 60529 (IP54)
    Display 1999 counts (3 1/2digits), Large LCD
    Operating temperature and humidity range 0 - 40ºC, relative humidity 85% (no condensation)
    Storage temperature and humidity range -20 - 60ºC, relative humidity 75% (no condensation)
    Insulation resistance 50MΩ or more / 1000V (between electrical circuit and enclosure)
    Sleep Function (1)Automatically enters Sleep mode in 3 minutes after the last switch operation (current consumption 75µA). This function doesn't work at voltage measurements. To exit from the Sleep mode, set the Function switch to OFF position once, and re-set it to the Range at which a measurement to be conducted.
    (2) Backlight turns off in 1 minute after it lights up.
    Power source DC 12V / R6(AA)(1.5V) × 8
    Dimension 167(L)×186(W)×89(D)mm
    Weight Approx. 965g (including batteries)
    Possible number of Measurements 1200 times or more
    (measure every 30 seconds at ×1/2 Range, lΔn=100mA)
    Accessories 7128A (Test leads)
    7129A (Test lead with alligator clip)
    8017 (Extension prod long) × 2
    9121 (Shoulder strap)
    9147 (Cord case)
    Instruction manual, R6(AA) × 8

    (*) Only the RCD type G (without trip out time-delay) can be tested at Auto Ramp Test,
    type S (time-delay) cannot be tested.