Atur jumlah dan catatan
Stok Total: Sisa 2
Subtotal
Rp948.000
YR1035+ High Precision 100V Battery Internal Resistance Tester New Probes !!
Rp948.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: Tools
YR1035+ ( New Enhance Probes )
100V High Precision Lithium Battery Internal Resistance Tester
WARNING: Max Volt 100V
Bisa juga untuk ukur lead acid, lithium ion, lithium polymer, lithium iron phosphate, alkaline, dry battery, nickel metal hydride, nickel cadmium, button battery, etc
True Four-wire 1Khz AC Sine Battery Internal Resistance Meter 0.00001Ω---200Ω Range.
Use ZR function to measure internal resistance below 5 milliohms for higher accuracy.
Main parameters:
Internal resistance measurement:
The precision format is: ±([precision percentage]+[least significant digit])
Range Resolution Accuracy
20mΩ 0.01mΩ 0.7%+7 (when ZR function is enabled)
200mΩ 0.1mΩ 0.5%+5
2Ω 0.001Ω 0.5%+5
20Ω 0.01Ω 0.5%+5
200Ω 0.1Ω 0.6%+5
The range of the gear is 5%-95%. When it is not within this range (less than 5% of the gear range, or greater than 95% of the gear range), the error may be greater than the above accuracy.
Voltage measurement:
Range resolution Accuracy ± (% reading + % range)
1V 0.00001V 0.15+0.015
10V 0.0001V 0.15+0.010
100V 0.001V 0.15+0.015
Positive and negative symmetric error ± (0.012% + 5 characters)
Temperature drift within normal operating temperature (10℃--40℃) 100ppm/℃
100V High Precision Lithium Battery Internal Resistance Tester
WARNING: Max Volt 100V
Bisa juga untuk ukur lead acid, lithium ion, lithium polymer, lithium iron phosphate, alkaline, dry battery, nickel metal hydride, nickel cadmium, button battery, etc
True Four-wire 1Khz AC Sine Battery Internal Resistance Meter 0.00001Ω---200Ω Range.
Use ZR function to measure internal resistance below 5 milliohms for higher accuracy.
Main parameters:
Internal resistance measurement:
The precision format is: ±([precision percentage]+[least significant digit])
Range Resolution Accuracy
20mΩ 0.01mΩ 0.7%+7 (when ZR function is enabled)
200mΩ 0.1mΩ 0.5%+5
2Ω 0.001Ω 0.5%+5
20Ω 0.01Ω 0.5%+5
200Ω 0.1Ω 0.6%+5
The range of the gear is 5%-95%. When it is not within this range (less than 5% of the gear range, or greater than 95% of the gear range), the error may be greater than the above accuracy.
Voltage measurement:
Range resolution Accuracy ± (% reading + % range)
1V 0.00001V 0.15+0.015
10V 0.0001V 0.15+0.010
100V 0.001V 0.15+0.015
Positive and negative symmetric error ± (0.012% + 5 characters)
Temperature drift within normal operating temperature (10℃--40℃) 100ppm/℃