Atur jumlah dan catatan
Stok Total: 17
Subtotal
Rp4.312.000
DFRobot Analog Dissolved Oxygen Sensor / Meter Kit For Arduino
Rp4.312.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: Semua Etalase
ππππ: πππππ ππππππππ πππππ ππππ ππππππππ ππ ππππ ππππππ πππππππππ
SKU: KA2005
Note:
1. The filling solution is 0.5 mol/L NaOH solution. You need to pour it in the membrane cap before use. Please be caution with the operation because the solution is corrosive. Please wear gloves! If the solution accidentally drops onto the skin, wash your skin with plenty of water immediately.
2. The oxygen permeable membrane in the membrane cap is sensitive and fragile. Be caution when handling with it. Fingernail and other sharp objects should be avoided.
FEATURES
ProbeοΌ
1. Galvanic probe, no need polarization time
2. Filling solution and membrane cap is replaceable, low maintenance cost
Signal Converter BoardοΌ
1. 3.3~5.5V wide-range power supply, compatible with most Arduino microcontroller
2. 0~3.0V analog output, compatible with all microcontrollers with ADC function.
3. Gravity interface, plug and play, easy to use
SPECIFICATION
Dissolved Oxygen Galvanic Probe
Detection Range: 0~20mg/L
Response Time: Up to 98% full response, within 90 seconds (25β)
Pressure Range: 0~50PSI
Electrode Service Life: 1 year (normal use)
Maintenance Period: Membrane Cap Replacement Period: 1~2 months (in muddy water); 4~5 months (in clean water) Filling Solution Replacement Period: Once every month
Cable Length: 2 meters
Signal Converter Board
Operating Voltage: 3.3~5.5V
Output Signal: 0~3.0V
Cable Connector: BNC
Galvanic Dissolved Oxygen Probe with Membrane Cap x1
Spare Membrane Cap x1
Signal Converter Board x1
Gravity Analog Sensor Cable x1
Waterproof Gasket x2
Screw Cap for BNC Connector x1
SKU: KA2005
Note:
1. The filling solution is 0.5 mol/L NaOH solution. You need to pour it in the membrane cap before use. Please be caution with the operation because the solution is corrosive. Please wear gloves! If the solution accidentally drops onto the skin, wash your skin with plenty of water immediately.
2. The oxygen permeable membrane in the membrane cap is sensitive and fragile. Be caution when handling with it. Fingernail and other sharp objects should be avoided.
FEATURES
ProbeοΌ
1. Galvanic probe, no need polarization time
2. Filling solution and membrane cap is replaceable, low maintenance cost
Signal Converter BoardοΌ
1. 3.3~5.5V wide-range power supply, compatible with most Arduino microcontroller
2. 0~3.0V analog output, compatible with all microcontrollers with ADC function.
3. Gravity interface, plug and play, easy to use
SPECIFICATION
Dissolved Oxygen Galvanic Probe
Detection Range: 0~20mg/L
Response Time: Up to 98% full response, within 90 seconds (25β)
Pressure Range: 0~50PSI
Electrode Service Life: 1 year (normal use)
Maintenance Period: Membrane Cap Replacement Period: 1~2 months (in muddy water); 4~5 months (in clean water) Filling Solution Replacement Period: Once every month
Cable Length: 2 meters
Signal Converter Board
Operating Voltage: 3.3~5.5V
Output Signal: 0~3.0V
Cable Connector: BNC
Galvanic Dissolved Oxygen Probe with Membrane Cap x1
Spare Membrane Cap x1
Signal Converter Board x1
Gravity Analog Sensor Cable x1
Waterproof Gasket x2
Screw Cap for BNC Connector x1
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan