Atur jumlah dan catatan
Stok: 25
Subtotal
Rp65.000
Modbus RTU RS485 Relay Module 5V 12V 1 2 4 8 Channel TTL Communication - 1 Channel | 12V
Rp65.000
Pilih ukuran: 1 Channel | 12V
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: F - Module Relay dan SSR
Modbus RTU 12V 1/2/4/8 Channel Relay Output Board Switch Input RS485 TTL Communication Network Expansion Board Relay Module
Harga tertera untuk 1 unit sesuai varian yang dipilih. Tersedia varian
*1 Channel 5V
*1 Channel 12V
*2 Channel 5V
*2 Channel 12V
*4 Channel 5V
*4 Channel 12V
*8 Channel 5V
*8 Channel 12V
Feature :
1.This is a 1/2/4/8 Channel 12V Relay Output Board Module.
2.Easy to install.
3.Good quality, durable.
4.Portable design,easy to operate.
5.Low power, high precision,RS485 / TTL Communication.
6.1/2/4/8 channel optocoupler isolation.
Specifications:
1. RS485 communication interface
2. TTL communication interface
3. 1/2/4/8 channel optocoupler isolation
4. A user button
5. A user LED indicator
6. A power indicator
7. Power terminal interface (12V power supply)
8. 1 input
9. 1 output
10.DC power carrier (12V power supply)
11. Power terminal interface (12V power supply)
Modbus RTU instruction :
Baud rate: 9600 8 NONE 1
Hexadecimal transmission
Hexadecimal reception
Operation Steps:
1. Software selection communication baud rate 9600 fixed
2. Set the address (device address used for communication)
The default setting is 1 for the instruction.
3.RS485 and TTL serial port selection. When using RS485 communication, DI connects to TXD and RO connects to RXD; when using TTL communication, both DI and RO connect to NC
Harga tertera untuk 1 unit sesuai varian yang dipilih. Tersedia varian
*1 Channel 5V
*1 Channel 12V
*2 Channel 5V
*2 Channel 12V
*4 Channel 5V
*4 Channel 12V
*8 Channel 5V
*8 Channel 12V
Feature :
1.This is a 1/2/4/8 Channel 12V Relay Output Board Module.
2.Easy to install.
3.Good quality, durable.
4.Portable design,easy to operate.
5.Low power, high precision,RS485 / TTL Communication.
6.1/2/4/8 channel optocoupler isolation.
Specifications:
1. RS485 communication interface
2. TTL communication interface
3. 1/2/4/8 channel optocoupler isolation
4. A user button
5. A user LED indicator
6. A power indicator
7. Power terminal interface (12V power supply)
8. 1 input
9. 1 output
10.DC power carrier (12V power supply)
11. Power terminal interface (12V power supply)
Modbus RTU instruction :
Baud rate: 9600 8 NONE 1
Hexadecimal transmission
Hexadecimal reception
Operation Steps:
1. Software selection communication baud rate 9600 fixed
2. Set the address (device address used for communication)
The default setting is 1 for the instruction.
3.RS485 and TTL serial port selection. When using RS485 communication, DI connects to TXD and RO connects to RXD; when using TTL communication, both DI and RO connect to NC
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan