Overcurrent Relay ABB SPAJ 140 C

Rp9.250.000
  • Kondisi: Baru
  • Min. Pemesanan: 1 Buah
  • Etalase: Semua Etalase
Brand : ABB

Type/Spesifikasi : SPAJ 140 C 
Combined overcurrent 
and earth-fault relay

The complete manual for the relay SPAJ 140 C contains the following submanuals: 
General relay description for SPAJ 140 C 1MRS 750629 
General characteristics of D type relay modules 1MRS 750066-MUM EN 
Combined overcurrent and earth-fault relay module 
type SPCJ 4D29 1MRS 750119 
Features Three-phase, low-set phase overcurrent unit 
with definite time or inverse definite minimum 
time (IDMT) characteristic 
Three-phase, high-set phase overcurrent unit 
with instantaneous or definite time function 
Low-set, non-directional earth-fault unit with 
definite time or inverse definite minimum time 
(IDMT) characteristic 
High-set, non-directional earth-fault unit with 
instantaneous or definite time function 
Built-in breaker failure protection function 
Two heavy-duty and four light-duty output 
relays with field-selectable configuration 
Extensive data communication capabilities over 
built-in serial port 
Outstanding design flexibility for easy selection 
of appropriate operation schemes for different 
applications 
Numerical display of setting values, measured 
values, memorized fault values, fault codes etc. 
Enhanced system reliability and availability due 
to continuous hardware and software self-super- 
vision with auto-diagnosis 
Powerful software support for setting and 
parametrizing of the relay and for recording of 
relay parameters with a portable PC. 
The combined overcurrent and earth-fault relay 
SPAJ 140 C is intended to be used for the 
selective short-circuit and earth-fault protection 
of radial feeders in solidly earthed, resistance 
earthed or impedance earthed power systems. 
The integrated protection relay includes a phase 
overcurrent unit and an earth-fault unit with 
flexible tripping and signalling facilities. The 
overcurrent and earth-fault relays can also be 
used inother applications requiring single-, two- 
or three-phase overcurrent protection and non- 
directional earth-fault protection. The com- 
bined overcurrent and earth-fault relay also fea- 
tures circuit breaker failure protection.