HONEYWELL C7035A 1031 uv flame detector - Photocell / Sensor / Sensor Api / Flame Sensor

Rp4.738.000
    HONEYWELL C7035A 1031 sensor / uv flame detector

    APPLICATION
    The C7027A, C7035A, C7044A and C7927A Minipeeper
    Ultraviolet Flame Detectors detect the ultraviolet radiation
    emitted by combustion flames. The flame detectors are used
    with Honeywell flame safeguard controls to provide flame
    supervision for gas, oil, or combination gas-oil burners.

    FEATURES
    • C7027A, C7035A, and C7044A Flame Detectors are
    used with R7249A, R7290A, R7749B and R7849A,B
    Amplifiers and the appropriate Honeywell controls.

    • C7035A has an integral collar threaded (internal1-11-1/2 NPSM) for mounting on a one-inch sight pipe.
    • C7035A housing meets Underwriters Laboratories Inc.requirements for rain tightness and complies with NEMA enclosure standards, types 4 and 4X.

    • Properly installed, the C7027A and C7035A are pressure rated for 5 psi.
    • C7035A ultraviolet radiation sensor tube is field replaceable.
    • Two C7027A, C7035A or C7044A Flame Detectors can be wired in parallel for difficult flame lighting
    installations.

    C7035A Minipeeper Ultraviolet
    Flame Detector:
    Flame Detection: End viewing.
    Ambient Operating Temperature Ratings: 0°F to 250°F
    (-18°C to +121°C), or -40°F to 250°F (-40°C to +121°C),
    depending on model.
    Maximum Pressure Rating: 5 psi ((34.5 kPa).
    Mounting: Collar with 1-11-1/2 NPSM internal threads for
    mounting on a 1 in. sight pipe. (The DIN approved
    C7035A1064 has 1-11 BSP.P1 threads.)
    Wiring Connections: Two 6 ft. [1.83 m], color-coded NEC
    Class 1 leadwires rated for 302°F (150°C). One model is
    available with 12 ft. (3.66 m) leadwires. Rear of detector
    has 1/2-14 NPSM internal threads for connecting to a
    conduit. The DIN-approved C7035A1064 has 1/2-14
    BSP-F threads.
    C7035A1056 has 12 ft (3.66 m) leadwires.
    C7035A1080 leadwire is rated for 600°F (204°C).
    Dimensions: See Fig. 2.
    Replacement Parts:
    129808 Flange Gasket.
    129464M Ultraviolet Sensing Tube, 0°F to 250°F (-18°C to
    +121°C).
    129464N Ultraviolet Sensing Tube, -40°F to +250°F (-40°C to
    121°C).




    Kebijakan Pengembalian & Penukaran BarangProduk yang telah dikirim dapat dikembalikan atau ditukar apabila memenuhi syarat & ketentuan berikut:

    Produk yang diterima berbeda spesifikasi dari yang tertera di iklan.
    Produk yang dikirim tidak sesuai dengan pesanan (beda tipe/spesifikasi).
    Produk yang dikirim berbeda merek dari yang dipesan.
    Produk tidak dapat dikembalikan apabila:

    Terjadi kesalahan pemesanan oleh pembeli (misalnya salah memilih merek atau spesifikasi).
    Barang sudah tidak dibutuhkan lagi setelah dipesan.
    Tidak disertakan video unboxing secara utuh, tanpa potongan dan tanpa editing (wajib).
    Pembeli salah pilih produk karena ketidaktahuan atau coba-coba.
    Terjadi kesalahan pengiriman oleh penjual, namun barang atau dus produk sudah dirusak oleh pembeli.
    Ada masalah dengan produk ini?

    ULASAN PEMBELI

    Toped Illustration

    Belum ada ulasan untuk produk ini

    Beli produk ini dan jadilah yang pertama memberikan ulasan