ECG Simulator MS400 / ECG Multiparameter Simulator /EKG Simulator
Rp5.550.000
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: Semua Etalase
SpecificationMS400 Multiparameter Simulator is a portable device, which can provide comprehensive physiological waveform to content general test and train requirement.It can check the monitor rapidly near the bed, also can test the quality warranty ofequipment, monitor and remote therapy equipment, At the same time,it can be used as the training of distinguishing from arrhythmia waveforms to the nurses.
3.5-inch color TFT touch-screen, 320*240 pixels, friendly operation interface.
Display the output waveforms synchronously, which is convenient for user to compare with the test equipment.
It integrates the functions of SD socket interface, user can output the custom waveform by this device.
Built-in templates list to provide the waveform that is expressed by each preset sequence number,which is convenient for searching.
Two operation interfaces:Chinese and English.
Operate with keystroke and touch-screen expediently and rapidly.
Built-in 3.7V/4000mAh(Rechargeable alkaline battery).
Optical external power: AC 220V, 50Hz or AC 120V, 60Hz
/Arrhythmia
Conventional: All leads have the same voltage with the II-lead as the reference
Amplitude: 0.5,1.0,1.5 and 2.0mV
The accuracy of Amplitude: ±2%
Rate: 15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340 and 350 BPM
artifacts: 50 or 60 Hz, muscle, baseline drift and breathing
The elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mV
The default: 80 BPM,1mV
Arrhythmia
Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial
Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min,
PVCs 12/min, PVCs 24/min, Freqent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5
PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
Premature Beat: Atrial Premature Atrial
3.5-inch color TFT touch-screen, 320*240 pixels, friendly operation interface.
Display the output waveforms synchronously, which is convenient for user to compare with the test equipment.
It integrates the functions of SD socket interface, user can output the custom waveform by this device.
Built-in templates list to provide the waveform that is expressed by each preset sequence number,which is convenient for searching.
Two operation interfaces:Chinese and English.
Operate with keystroke and touch-screen expediently and rapidly.
Built-in 3.7V/4000mAh(Rechargeable alkaline battery).
Optical external power: AC 220V, 50Hz or AC 120V, 60Hz
/Arrhythmia
Conventional: All leads have the same voltage with the II-lead as the reference
Amplitude: 0.5,1.0,1.5 and 2.0mV
The accuracy of Amplitude: ±2%
Rate: 15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340 and 350 BPM
artifacts: 50 or 60 Hz, muscle, baseline drift and breathing
The elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mV
The default: 80 BPM,1mV
Arrhythmia
Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial
Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min,
PVCs 12/min, PVCs 24/min, Freqent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5
PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
Premature Beat: Atrial Premature Atrial