Specifications Infusomats
Terumo TE-172
Accuracy (nominal value)
within ± 3% [Conditions] Set syringes specified for syringes Infusomats Terufusion type E, a solution of water / saline solution, the testing of the second hour flow rate of 1.0 ml / hour and a temperature of 25 ° C.
Within ± 5% [Conditions] Set syringes specified for syringes Infusomats Terufusion . solution of water / saline solution, the testing of the second hour. flow rate 1.0 ml / hour and more, temperature 25 ° C.
The flow rate
0,1-1200 ml / h (0 1-99.9 ml / hr in steps of 0.1 ml / h, 100-1200 ml / hr in steps of 1 ml / hour). Using internal switch can change the flow rate in increments of 1 ml / hour throughout the tuning range.
Limiting the volume delivered
1-999,9 ml or "-" (no restrictions delivered volume).
The delivered volume
0,0-999,9 ml (0,0-99.9 mL increments of 0.1 ml 100-9999 ml increments by 1 ml) using the internal switch, the indications of the inputted screen will be displayed with step 1 ml throughout the range.
Emptying
than 500 ml / hour.
Determination occlusion
13,3-133,3 kPa
pressure
level for determining blockage pressure in the above range
function closure
When the total amount of fluid delivered reaches a pre-set level limitation delivered volume indicator and an audible alarm informs attendants
call alarm system nurse
Terumo TE-172
Accuracy (nominal value)
within ± 3% [Conditions] Set syringes specified for syringes Infusomats Terufusion type E, a solution of water / saline solution, the testing of the second hour flow rate of 1.0 ml / hour and a temperature of 25 ° C.
Within ± 5% [Conditions] Set syringes specified for syringes Infusomats Terufusion . solution of water / saline solution, the testing of the second hour. flow rate 1.0 ml / hour and more, temperature 25 ° C.
The flow rate
0,1-1200 ml / h (0 1-99.9 ml / hr in steps of 0.1 ml / h, 100-1200 ml / hr in steps of 1 ml / hour). Using internal switch can change the flow rate in increments of 1 ml / hour throughout the tuning range.
Limiting the volume delivered
1-999,9 ml or "-" (no restrictions delivered volume).
The delivered volume
0,0-999,9 ml (0,0-99.9 mL increments of 0.1 ml 100-9999 ml increments by 1 ml) using the internal switch, the indications of the inputted screen will be displayed with step 1 ml throughout the range.
Emptying
than 500 ml / hour.
Determination occlusion
13,3-133,3 kPa
pressure
level for determining blockage pressure in the above range
function closure
When the total amount of fluid delivered reaches a pre-set level limitation delivered volume indicator and an audible alarm informs attendants
call alarm system nurse
Ada masalah dengan produk ini?