Download Tokopedia App
Tentang TokopediaMulai Berjualan PromoTokopedia Care
tokopedia-logo
Kategori
Atur jumlah dan catatan

Stok Total: Sisa 1

Subtotal

Rp6.700.000

contec ms400 simulator parameter ecg ekg contecms400

Rp6.700.000
  • Kondisi: Baru
  • Min. Pemesanan: 1 Buah
  • Etalase: Semua Etalase
STOCK CONTEC NEW BRAND MS400 MULTI-PARAMETER PATIENT SIMULATOR,ECG SIMULATOR Introduction MS400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it can be tested in where the monitor is used. Parameters: ECG Conventional: All leads have the same voltage with the II-lead as the reference Amplitude: 0.5,1.0,1.5 and 2.0mV ECG Rate: 15,20,25,30,40,60,80,100,120,140,160,180 200,220,240,260,280,300,320,340 and 350 BPM ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV Arrhythmia Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia Ventricular: Vent Fib (coarse), Vent Fib (fine), PVCs 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole Premature Beat: Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R on T LV Focus, PVC2 RV Focus, PVC2 E RV Focus, R on T RV Focus, Multifocal PVC Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block Four IBP Channels The default: 00/00mmHg Dynamic IBP(unit: mmHg) Channel 1: Artery: 120/80 Radial: 120/80 Left Ventricle: 120/00 Right Ventricle: 25/00 Channel 2: Artery: 120/80 Radial: 120/80 Left Ventricle: 120/00 Right Atrium(CVP): 15/10 Right Ventricle: 25/00 Pulmonary Artery: 25/10 Pulmonary Wedge: 10/2 Left Atrium: 14/4 Channel 3: Artery: 120/80 Radial: 120/80 Left Ventricle: 120/00 Right Atrium(CVP): 15/10 Right Ventricle: 25/00 Pulmonary Artery: 25/10 Pulmonary Wedge: 10/2 Left Atrium: 14/4 Channel 4: Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge) package include: - unit ms400 - adapter - manual book

Tips buat cek keaslian produk

Yuk, baca sebelum beli produk kesehatan ini. Selengkapnya
Ada masalah dengan produk ini?

ULASAN PEMBELI

Toped Illustration

Belum ada ulasan untuk produk ini

Beli produk ini dan jadilah yang pertama memberikan ulasan