Atur jumlah dan catatan
Stok Total: Sisa 1
Subtotal
Rp86.900.000
Simple automatic titrator SI Analytics Titrator TitroLine 5000
Rp86.900.000
Measuring input pH/mV pH/mV-input with elektrode socket according to DIN 19262. BNC via adapter. Reference electrode 1 x 4 mm socket
Measuring range pH/accuracy - 3,0… 17,00 / 0,05 +/- 1 digit
Measuring range mV/accuracy - 1900…1900/ 1,0 +/- 1 digit
Measuring input temperature: Connector for Pt 1000 / NTC 30 KOhm (Sockets: 2 × 4 mm)
Measuring range temperature - 30 …115 °C / 0,5 K +/- 1 digit
Interfaces: 2 × USB (1 USB-A and 1 × USB-B), 2 × RS-232-C
Dosing units 20 ml; 50ml also usable
Resolution (steps): 8000 steps
Dosing accuracy: according to DIN ISO 8655, part 3:
accuracy: < 0.15 %
precision: < 0.05 %
Display 3.5 inches - 1/4 VGA TFT graphic color display with 320 x 240 pixels
Housing material Polypropylene
Dimensions 135 x 310 x 205 mm (W x H x D), height with dosing unit, without stirrer
Front keyboard Polyester
Material dosing unit/valve Valve: PTFE/ETFE;
Cylinder: borosilikate glass 3.3 (DURAN)
Hoses: (FEP, blue)
UV Cover: Ultem
Weight 2 kg
Ambient conditions Ambient temperature: + 10 ... + 40 °C for operation and storage Humidity according to EN 61 010, Part 1: max. relative humidity 80 % for temperatures up to 31 °C, linear decrease down to 50 % relative humidity at a temperature of 40 °C
Power supply: 100-240 V; 50/60 Hz, power input: 30 VA
CE-sign: EMC compatibility according to the Council Directive: 2004/108/EG; applied harmonized standards: EN 61326-1:2006
Low-voltage directive according to the Council Directive 2006/95/EG Testing basis EN 61 010, part 1
Magnetic stirrer TM 50, for glass vessels up to maximale 500 ml, speed can be adjusted without discrete steps 0 - 1000 min-1, connection to TITRONIC 300 and TitroLine 5000, including stand rod holder TZ 3885
pH-Electrode Glass shaft, 3 x ceramic junction, gel electrolyte, Silamid-reference system, temperature sensor NTC 30 kOhm, sphere membrane, A-glass, 1 m fixed cable with DIN + 4 mm banana plug, length 120 mm, 12 mm Ø, -5...+80 °C, 0...14 pH
Call. 081246390570
Measuring range pH/accuracy - 3,0… 17,00 / 0,05 +/- 1 digit
Measuring range mV/accuracy - 1900…1900/ 1,0 +/- 1 digit
Measuring input temperature: Connector for Pt 1000 / NTC 30 KOhm (Sockets: 2 × 4 mm)
Measuring range temperature - 30 …115 °C / 0,5 K +/- 1 digit
Interfaces: 2 × USB (1 USB-A and 1 × USB-B), 2 × RS-232-C
Dosing units 20 ml; 50ml also usable
Resolution (steps): 8000 steps
Dosing accuracy: according to DIN ISO 8655, part 3:
accuracy: < 0.15 %
precision: < 0.05 %
Display 3.5 inches - 1/4 VGA TFT graphic color display with 320 x 240 pixels
Housing material Polypropylene
Dimensions 135 x 310 x 205 mm (W x H x D), height with dosing unit, without stirrer
Front keyboard Polyester
Material dosing unit/valve Valve: PTFE/ETFE;
Cylinder: borosilikate glass 3.3 (DURAN)
Hoses: (FEP, blue)
UV Cover: Ultem
Weight 2 kg
Ambient conditions Ambient temperature: + 10 ... + 40 °C for operation and storage Humidity according to EN 61 010, Part 1: max. relative humidity 80 % for temperatures up to 31 °C, linear decrease down to 50 % relative humidity at a temperature of 40 °C
Power supply: 100-240 V; 50/60 Hz, power input: 30 VA
CE-sign: EMC compatibility according to the Council Directive: 2004/108/EG; applied harmonized standards: EN 61326-1:2006
Low-voltage directive according to the Council Directive 2006/95/EG Testing basis EN 61 010, part 1
Magnetic stirrer TM 50, for glass vessels up to maximale 500 ml, speed can be adjusted without discrete steps 0 - 1000 min-1, connection to TITRONIC 300 and TitroLine 5000, including stand rod holder TZ 3885
pH-Electrode Glass shaft, 3 x ceramic junction, gel electrolyte, Silamid-reference system, temperature sensor NTC 30 kOhm, sphere membrane, A-glass, 1 m fixed cable with DIN + 4 mm banana plug, length 120 mm, 12 mm Ø, -5...+80 °C, 0...14 pH
Call. 081246390570
Ada masalah dengan produk ini?
ULASAN PEMBELI

Belum ada ulasan untuk produk ini
Beli produk ini dan jadilah yang pertama memberikan ulasan