Atur jumlah dan catatan
Stok: 11
Subtotal
Rp4.000.000
200mL Hydrothermal Autoclave Reactor Teflon Chamber Synthesis - 200mL
Rp4.000.000
Pilih ukuran: 200mL
- Kondisi: Baru
- Min. Pemesanan: 1 Buah
- Etalase: Alat Lab
Ready Stock ya,
50mL klik disini : https://tokopedia.com/m4xprima/hydrothermal-50ml-100ml-200ml-autoclave-reactor-teflon-chamber-synthesis-50-100-200-ml
100mL klik disini : https://tokopedia.com/m4xprima/100ml-hydrothermal-autoclave-reactor-teflon-chamber-synthesis-1730814935494068080
200mL Klink disini : https://tokopedia.com/m4xprima/200ml-hydrothermal-autoclave-reactor-teflon-chamber-synthesis-1730814970221070192
SIlahkan pilih salah satu saat order ya,
Features:
1, High quality 304 Stainless steel structure, durable and gas-tight
2, Elegant design, easy to operate
3, PTFE inner chamber to minimize corrosion
4, The feeding coeffficient should be less than 0.8.
5, Make sure the temperature side is below the boiling point before opening the vessel lid
6, Thoroughly clean the reactor after operation
Specifications:
1. It is recommended that the external heating temperature should not exceed 200 ℃,
the heating rate is ≤ 5 ℃/min, the temperature can be controlled by PID temperature control system, the cooling rate is ≤ 5C/min, and the safety pressure is 3MPa.
2. When the reaction is completed, the kettle cover can be opened only after the kettle body is naturally cooled to room temperature. It must not be disassembled under pressure.
3. The filling degree in the kettle should not exceed 80%
50mL klik disini : https://tokopedia.com/m4xprima/hydrothermal-50ml-100ml-200ml-autoclave-reactor-teflon-chamber-synthesis-50-100-200-ml
100mL klik disini : https://tokopedia.com/m4xprima/100ml-hydrothermal-autoclave-reactor-teflon-chamber-synthesis-1730814935494068080
200mL Klink disini : https://tokopedia.com/m4xprima/200ml-hydrothermal-autoclave-reactor-teflon-chamber-synthesis-1730814970221070192
SIlahkan pilih salah satu saat order ya,
Features:
1, High quality 304 Stainless steel structure, durable and gas-tight
2, Elegant design, easy to operate
3, PTFE inner chamber to minimize corrosion
4, The feeding coeffficient should be less than 0.8.
5, Make sure the temperature side is below the boiling point before opening the vessel lid
6, Thoroughly clean the reactor after operation
Specifications:
1. It is recommended that the external heating temperature should not exceed 200 ℃,
the heating rate is ≤ 5 ℃/min, the temperature can be controlled by PID temperature control system, the cooling rate is ≤ 5C/min, and the safety pressure is 3MPa.
2. When the reaction is completed, the kettle cover can be opened only after the kettle body is naturally cooled to room temperature. It must not be disassembled under pressure.
3. The filling degree in the kettle should not exceed 80%